Published December 1992 | Version v1
Report Restricted

Improved HYLIFE-II heat transport system and steam power plant: Impact on performance and cost of electricity

  • 1. Univ. of California, Davis, CA (United States). Dept. of Mechanical, Aeronautical and Materials Engineering

Description

The HYLIFE-II conceptual design has evolved and improved continually over the past four years to its present form. This paper describes the latest FY92 versions, Reference Case H1 (nominally 1 GWe net output) and the Enhanced Case HE (nominally 2 GWe net output), which take advantage of improvements in the tritium management system to eliminate the intermediate loop and the intermediate heat exchangers (IHX's). The improvements in the heat transport system and the steam power plant are described and the resulting cost reductions are evaluated. The new estimated cost of electricity (in 1990 dollars) is 6.6 cents/kWh for Reference Case H1 and 4.7 cents/kWh for the Enhanced Case

Availability note (English)

MF available from INIS under the Report Number; Also available from OSTI as DE93017945; NTIS; US Govt. Printing Office Dep.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Additional titles

Subtitle (English)
Final report for fiscal year 1992

Publishing Information

Imprint Pagination
109 p.
Report number
UCRL-ID--113266

Optional Information

Contract/Grant/Project number
Contract W-7405-ENG-48
Funding organization
USDOE, Washington, DC (United States).