Renal scintigraphy and clearance before and after transluminal angioplasty of a renal artery stenosis
Creators
- 1. Frankfurt Univ. (Germany). Abt. fuer Nuklearmedizin
Description
Nuclear medicine results before, early and late after percutaneous transluminal angioplasty (PTA) were evaluated. On the one hand this study was based on the results of the I-131-Hippuran clearance according to Oberhausen, including the time to maximum (Tmax) and half life time of renal elimination (EHWZ). On the other hand data from renal scintigraphy with Tc-99m-DTPA (perfusion and nephrographic phase) were used. Values of all split functions exhibit a progressive improvement between early and late controls. Glomerular filtration fraction (GFR) of the post-stenotic kidney increases immediately after PTA from 30% (before) to 35% (early after). EHWZ (before 17.6, early after 14.1, late after 10,8 min) and Tmax inversely correlat with GFR. I-131-Hippuran clearance indicates only a late increase (before 306, early after 309, late after 317 ml/min). According to this retrospective study GFR as well as Tmax and EHWZ (partially GFR dependent parameters) are most suitable in the follow up after PTA of a renal artery stenosis. (orig.)
Abstract (German)
Nuklearmedizinische Befunde vor, frueh und spaet nach perkutaner transluminaler Angioplastie (PTA) wurden ausgewertet. Zum einen handelte es sich um die Ergebnisse einer seitengetrennten I-131-Hippuranclearance nach OBERHAUSEN, einschliesslich der Bestimmung des Kurvenmaximums (Tmax) und der Eliminationshalbwertzeit (EHWZ) aus den Nephrographiekurven. Zum anderen wurden Befunde der Nierenfunktionsszintigraphie mit Tc-99m-DTPA hinsichtlich der Perfusions-(Radionuklidangiographie) und nephrographischen Phase evaluiert. Alle Partialfunktionen liessen nach PTA eine progressive Besserung zwischen Frueh- und Spaetkontrolle erkennen. Die glomerulaere Filtrationsrate verbesserte sich sofort nach PTA von 30 auf 35%. Parallel verhielten sich EHWZ (vor 17,6, frueh nach 14,1, spaet nach 10,8 min) und Tmax. Die Verbesserung der I-131-Hippuranclearance liess sich erst bei den Spaet-Kontrollen nachweisen (vor 306, frueh nach 309, spaet nach 317 ml/min). Aufgrund dieser retrospektiven Studie scheinen die GFR sowie Tmax und vor allem die EHWZ besonders gut zur Verlaufskontrolle einer Nierenarterienstenose vor und nach PTA geeignet. (orig.)Additional details
Additional titles
- Original title (German)
- Nierenfunktions-Szintigraphie und Clearance zur Erfolgsbeurteilung einer transluminalen Angioplastie bei Nierenarterienstenosen
Publishing Information
- Journal Title
- Nuklearmediziner
- Journal Volume
- 14
- Journal Issue
- 5
- Series
- Nuklearmediziner.
- Journal Page Range
- 241-248
- ISSN
- 0723-7065
- CODEN
- NKLZD
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 23039567
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ARTERIES; BLOOD FLOW; DIAGNOSIS; DYNAMIC FUNCTION STUDIES; FEASIBILITY STUDIES; HIPPURAN; IODINE 131; ISOMERIC NUCLEI; KIDNEYS; PATIENTS; RADIOPHARMACEUTICALS; RENAL CLEARANCE; SCINTISCANNING; SURGERY; TECHNETIUM COMPLEXES; TECHNETIUM 99; UROGENITAL SYSTEM DISEASES; VASCULAR DISEASES
- Descriptors DEC
- ANIMALS; BETA DECAY RADIOISOTOPES; BETA-MINUS DECAY RADIOISOTOPES; BLOOD VESSELS; BODY; CARDIOVASCULAR SYSTEM; CLEARANCE; COMPLEXES; CONTRAST MEDIA; COUNTING TECHNIQUES; DAYS LIVING RADIOISOTOPES; DIAGNOSTIC TECHNIQUES; DISEASES; DRUGS; EXCRETION; HOURS LIVING RADIOISOTOPES; INTERMEDIATE MASS NUCLEI; INTERNAL CONVERSION RADIOISOTO; IODINE ISOTOPES; ISOMERIC TRANSITION ISOTOPES; ISOTOPES; LABELLED COMPOUNDS; MAMMALS; MAN; MATERIALS; MEDICINE; NUCLEI; ODD-EVEN NUCLEI; ORGANS; PRIMATES; RADIOACTIVE MATERIALS; RADIOISOTOPE SCANNING; RADIOISOTOPES; TECHNETIUM ISOTOPES; TRANSITION ELEMENT COMPLEXES; VERTEBRATES; YEARS LIVING RADIOISOTOPES