Published May 2, 1989
| Version v1
Journal article
Simultaneous determination of four components by X-ray spectrometry after 14 MeV neutron activation
Creators
- 1. Hungarian Academy of Sciences, Budapest (Hungary). Central Research Inst. for Physics
Description
14 MeV neutron activation followed by X-ray spectrometry was applied to the simultaneous nondestructive determination of cadmium, antimony and bromine, utilizing praseodymium as an internal standard. The results of analysis show a relative error not higher than +-5%, when the samples were diluted with H3BO3 (≅90%) to minimize the interelement effects. (author) 9 refs.; 1 fig.; 2 tabs
Additional details
Publishing Information
- Journal Title
- Journal of Radioanalytical and Nuclear Chemistry
- Journal Volume
- 136
- Journal Issue
- 1
- Series
- J. Radioanal. Nucl. Chem. ;Letters.
- Journal Page Range
- 25-33
- ISSN
- 0236-5731
- CODEN
- JRNCD
INIS
- Country of Publication
- Hungary
- Country of Input or Organization
- Hungary
- INIS RN
- 21009458
- Subject category
- S37: INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL CHEMISTRY;
- Descriptors DEI
- ANTIMONY; BORIC ACID; BROMINE; CADMIUM; CALIBRATION STANDARDS; DILUTION; ERRORS; NEUTRON ACTIVATION ANALYSIS; NEUTRON REACTIONS; PRASEODYMIUM; X-RAY EMISSION ANALYSIS
- Descriptors DEC
- ACTIVATION ANALYSIS; BARYON REACTIONS; BORON COMPOUNDS; CHEMICAL ANALYSIS; ELEMENTS; HADRON REACTIONS; HALOGENS; HYDROGEN COMPOUNDS; INORGANIC ACIDS; INORGANIC COMPOUNDS; METALS; NONDESTRUCTIVE ANALYSIS; NONMETALS; NUCLEAR REACTIONS; NUCLEON REACTIONS; OXYGEN COMPOUNDS; RARE EARTHS