Published 2006 | Version v1
Book

Design Issues Affecting Pipings Associated with a New Moisture Separator Reheater

  • 1. Plant Design Department, Korea Power Engineering Company, Inc., 360-9 Mabuk-dong, Giheung-gu, Yongin-si, Gyeonggi-do, 449-713 (Korea, Republic of)

Description

This paper summarizes the piping design effects on a New Moisture Separator Reheater (MSR) in Shin-Kori Nuclear Power Plant Units 1 and 2 (SKN 1 and 2) being under the construction in Korea. This SKN 1 and 2 has the same arrangement of a Turbine-Generator set as one of Korea Standard Nuclear Plant Units ( OPR 1000 ) in commercial operation. The Turbine-Generator Supplier has developed a new Moisture Separator Reheater which has first and second stage heating steam supply connections respectively, at both ends of the shell side of the vessel in comparison to MSR of OPR 1000 which has first and second stage heating steam supply connections at only one end. The different locations of reheaters in MSR cause changes in the associated pipings such as 2. stage reheater heating steam, 2. stage reheater drain, shell drain, drain tank location and tank condensate drainage pipings. (authors)

Part of:
Validation of the TRACE Code Against Post-Dryout Experiments in Tubes and Annuli

Additional details

Publishing Information

Publisher
American Nuclear Society - ANS
Imprint Place
La Grange Park (United States)
ISBN
0-89448-698-5
Imprint Title
Proceedings of the 2006 international congress on advances in nuclear power plants - ICAPP'06
Imprint Pagination
2734 p.
Journal Page Range
p. 210-217

Conference

Title
2006 International congress on advances in nuclear power plants - ICAPP'06
Dates
4-8 Jun 2006
Place
Reno - Nevada (United States)

Optional Information

Notes
5 refs.