Published October 1995 | Version v1
Report

Stability study of ATF (Accelerator Test Facility) 80 MeV injector linac

  • 1. National Lab. for High Energy Physics, Tsukuba, Ibaraki (Japan)

Description

A beam stability test was carried out at ATF (Accelerator Test Facility) 80 MeV injector linac. The test was performed by taking data of each monitor in pulse to pulse base. A data acquisition system which consists of a PC and a GPIB network was used for the test. In order to analyze the data, 'Correlation plot' method is used which is effective to find out some source of the observed the beam fluctuation. This paper describes the result of the stability measurement and the comparison between ATF injector and SLC injector. (author)

Part of:
Proceedings of the 10th symposium on accelerator science and technology

Additional details

Publishing Information

Imprint Title
Proceedings of the 10th symposium on accelerator science and technology
Imprint Pagination
490 p.
Journal Page Range
p. 171-173.
Report number
JAERI-Conf--95-021

Conference

Title
10. symposium on accelerator science and technology.
Dates
25-27 Oct 1995.
Place
Hitachinaka, Ibaraki (Japan).

Optional Information