Determination of preliminary plant operation logic for KALIMER

  • 1. KAERI, Taejon (Korea, Republic of)

Description

In the KALIMER design, once-through helical coil steam generators are used to generate superheat steam. The once-through steam generator has its unique operational characteristics and a preliminary scheme for plant operation temperature. The operation temperature scheme determines typical thermal behaviors of the main systems in the plant and is the starting point in setting up the plant operation logic. Control features in plant operation between PWR and LMR are discussed including several technical aspects that need to be considered in developing the plant operation logic. Using HSGSA-RE code, calculational results on the operation logic are obtained. Based on the results, a preliminary operation logic for KALIMER is proposed

Part of:
Proceedings of the Korean Nuclear Society spring meeting

Additional details

Publishing Information

Publisher
KNS
Imprint Place
Taejon (Korea, Republic of)
Imprint Title
Proceedings of the Korean Nuclear Society spring meeting
Imprint Pagination
[one CD-ROM]
Journal Page Range
[7 p.]

Conference

Title
1999 spring meeting of the Korean Nuclear Society
Dates
28-29 May 1999
Place
Pohang (Korea, Republic of)

INIS

Country of Publication
Korea, Republic of
Country of Input or Organization
Korea, Republic of
INIS RN
33042340
Subject category
S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
Resource subtype / Literary indicator
Conference, Non-conventional Literature
Descriptors DEI
COMPUTER CALCULATIONS; LIQUID METAL COOLED REACTORS; PWR TYPE REACTORS; STEAM GENERATORS; SUPERHEATING; U CODES
Descriptors DEC
BOILERS; COMPUTER CODES; ENRICHED URANIUM REACTORS; HEATING; POWER REACTORS; REACTORS; THERMAL REACTORS; VAPOR GENERATORS; WATER COOLED REACTORS; WATER MODERATED REACTORS

Optional Information

Notes
11 refs, 1 tab