Description

This paper presents an investigation of the usefulness of the intrinsic 28Si(n,α)25Mg and 28Si(n,p)28Al reactions in silicon surface barrier detectors for measurements of ion temperatures in D-T fusion plasmas and of D-T fusion neutron flux. For a 14-MeV neutron-generator narrow energy-line source, the energy resolution (∼1.5%), detection efficiency and useful count rates have been determined. Based on these results, for a 100 ms time bin, D-T plasma ion temperatures from 2 to 6 keV can be determined from the FWHM of the neutron-induced α spectral lines, with the error estimated to be 25% to 5%, respectively. The maximum intrinsic detection efficiency for a nominal 1500 μm thick detector is ∼6 x 10-4