MRI definition of target volumes using fuzzy logic method for three-dimensional conformal radiation therapy

Description

Purpose: Three-dimensional (3D) volume determination is one of the most important problems in conformal radiation therapy. Techniques of volume determination from tomographic medical imaging are usually based on two-dimensional (2D) contour definition with the result dependent on the segmentation method used, as well as on the user's manual procedure. The goal of this work is to describe and evaluate a new method that reduces the inaccuracies generally observed in the 2D contour definition and 3D volume reconstruction process. Methods and Materials: This new method has been developed by integrating the fuzziness in the 3D volume definition. It first defines semiautomatically a minimal 2D contour on each slice that definitely contains the volume and a maximal 2D contour that definitely does not contain the volume. The fuzziness region in between is processed using possibility functions in possibility theory. A volume of voxels, including the membership degree to the target volume, is then created on each slice axis, taking into account the slice position and slice profile. A resulting fuzzy volume is obtained after data fusion between multiorientation slices. Different studies have been designed to evaluate and compare this new method of target volume reconstruction and a classical reconstruction method. First, target definition accuracy and robustness were studied on phantom targets. Second, intra- and interobserver variations were studied on radiosurgery clinical cases. Results: The absolute volume errors are less than or equal to 1.5% for phantom volumes calculated by the fuzzy logic method, whereas the values obtained with the classical method are much larger than the actual volumes (absolute volume errors up to 72%). With increasing MRI slice thickness (1 mm to 8 mm), the phantom volumes calculated by the classical method are increasing exponentially with a maximum absolute error up to 300%. In contrast, the absolute volume errors are less than 12% for phantom volumes calculated by the fuzzy logic method. On radiosurgery clinical cases, target volumes defined by the fuzzy logic method are about half of the size of volumes defined by the classical method. Also, intra- and interobserver variations slightly decrease with the fuzzy logic method, resulting in the definition of a better common volume fraction. Conclusion: Our fuzzy logic method shows accurate, robust, and reproducible results on phantoms and clinical targets imaged on MRI

Additional details

Identifiers

PII
S0360301602038294;

Publishing Information

Journal Title
International Journal of Radiation Oncology, Biology and Physics
Journal Volume
55
Journal Issue
1
Journal Page Range
p. 225-233
ISSN
0360-3016
CODEN
IOBPD3

INIS

Country of Publication
United States
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
34012697
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
ACCURACY; ERRORS; FUZZY LOGIC; NMR IMAGING; PHANTOMS; RADIOTHERAPY; SPATIAL DOSE DISTRIBUTIONS; VOLUME
Descriptors DEC
DIAGNOSTIC TECHNIQUES; MATHEMATICAL LOGIC; MEDICINE; MOCKUP; NUCLEAR MEDICINE; RADIATION DOSE DISTRIBUTIONS; RADIOLOGY; STRUCTURAL MODELS; THERAPY

Optional Information

Copyright
Copyright (c) 2003 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.