Published November 1, 2001
| Version v1
Journal article
Optimising the LHCb VELO detector
Creators
Description
Possible new layouts of the LHCb Vertex Locator (VELO) have been compared with the existing baseline design outlined in the Technical Proposal. Based on a comparison of essential figures of merit, namely vertex resolutions, event selection efficiencies, trigger performance and technical constraints, an updated baseline design is proposed
Additional details
Identifiers
- PII
- S0168900201011391;
Publishing Information
- Journal Title
- Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
- Journal Volume
- 473
- Journal Issue
- 1-2
- Journal Page Range
- p. 163-166
- ISSN
- 0168-9002
- CODEN
- NIMAER
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- Germany
- INIS RN
- 34037634
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Descriptors DEI
- EFFICIENCY; OPTIMIZATION; PARTICLE DISCRIMINATION; PARTICLE TRACKS; POSITION SENSITIVE DETECTORS; SPATIAL RESOLUTION
- Descriptors DEC
- MEASURING INSTRUMENTS; PARTICLE IDENTIFICATION; RADIATION DETECTORS; RESOLUTION
Optional Information
- Copyright