Quality assurance network: The European pilot study
- 1. Institut Gustave Roussa, Villejuif (France). Service de Physique
- 2. University Hospital, Leuven (Belgium)
Description
Based on the IAEA/WHO experience in mailed dosimetry, a Quality Assurance (QA) Network, sponsored by the EC committee ''Europe against Cancer'', has been set up in 1991 for all European centres. Besides a survey of radiotherapy infrastructure, the project includes three measurement steps: primarily, a check of beam output and quality in reference conditions with a mailed TLD-procedure, in a second step, the mailed verification of other beam data and dose calculation procedures with multipurpose phantom, and finally in vivo dosimetry at the individual patient levels with mailed dosimeters. The results concerning 162 beams from 85 centres are analysed (58 60Co beams and 104 X-ray beams). 27 beams present minor deviations (3 to 6%) and 15 beams (4/58 60Co beams and 11/104 X-ray beams) from 11 centres present major deviations (≥ 6%). The analysis shows that 17/27 minor deviations and all major deviations have been detected in centres which have not benefited from an external check during the last five years; in 14 out of 15 large deviations, the measured dose is smaller than the stated dose. In most centres with major deviation, the physicists did not have the necessary experience and did not calibrate regularly the beams. In 6 centres out of 11 there was no dosimeter or the dosimeter available has not been calibrated recently. In 3 centres, the physicist did not give any explanations. The conclusions concerning the second step (multipurpose phantom), outline the larger magnitude of the deviations for off axis points, oblique surface and the use of wedge filters. (author). 32 refs, 7 figs, 2 tabs
Files
28017935.pdf
Files
(669.6 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:d3610e0599ff9b498fa25c14a1159024
|
669.6 kB | Preview Download |
Additional details
Publishing Information
- Imprint Title
- Radiation dose in radiotherapy from prescription to delivery
- Imprint Pagination
- 293 p.
- Journal Page Range
- p. 213-234.
- ISSN
- 1011-4289
- Report number
- IAEA-TECDOC--896
Conference
- Title
- Radiation dose in radiotherapy from prescription to delivery.
- Acronym
- Interregional seminar on radiotherapy dosimetry
- Dates
- 27-30 Aug 1994.
- Place
- Rio de Janeiro (Brazil).
INIS
- Country of Publication
- International Atomic Energy Agency (IAEA)
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 28017935
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY; S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- CARCINOMAS; COBALT 60; DOSIMETRY; EUROPE; PATIENTS; QUALITY ASSURANCE; RADIATION SOURCES; RADIOTHERAPY; X-RAY SOURCES
- Descriptors DEC
- ANIMALS; BETA DECAY RADIOISOTOPES; BETA-MINUS DECAY RADIOISOTOPES; COBALT ISOTOPES; DISEASES; INTERMEDIATE MASS NUCLEI; INTERNAL CONVERSION RADIOISOTOPES; ISOMERIC TRANSITION ISOTOPES; ISOTOPES; MAMMALS; MAN; MEDICINE; MINUTES LIVING RADIOISOTOPES; NEOPLASMS; NUCLEI; ODD-ODD NUCLEI; PRIMATES; RADIOISOTOPES; THERAPY; VERTEBRATES; YEARS LIVING RADIOISOTOPES