Neutron measurements in radiotherapy: A method to correct neutron sensitive devices for parasitic photon response
Creators
- 1. Servicio de Radiofísica, Hospital Universitario Virgen Macarena, Sevilla (Spain)
- 2. Departamento de Fisiología Médica y Biofísica, Universidad de Sevilla (Spain)
- 3. Politecnico di Milano, Dipartimento di Ingegneria Nuclear, Milano (Italy)
- 4. Laboratori Nazionali di Frascati, Istituto Nazionale di Fisica Nucleare (INFN) (Italy)
- 5. Instituto de Física, Pontificia Universidad Católica de Chile, Santiago (Chile)
Description
One of the major causes of secondary malignancies after radiotherapy treatments are peripheral doses, known to increase for some newer techniques (such as IMRT or VMAT). For accelerators operating above 10 MV, neutrons can represent important contribution to peripheral doses. This neutron contamination can be measured using different passive or active techniques, available in the literature. As far as active (or direct-reading) procedures are concerned, a major issue is represented by their parasitic photon sensitivity, which can significantly affect the measurement when the point of test is located near to the field-edge. This work proposes a simple method to estimate the unwanted photon contribution to these neutrons. As a relevant case study, the use of a recently neutron sensor for "in-phantom" measurements in high-energy machines was considered. The method, called "Dual Energy Photon Subtraction" (DEPS), requires pairs of measurements performed for the same treatment, in low-energy (6 MV) and high energy (e.g. 15 MV) fields. It assumes that the peripheral photon dose (PPD) at a fixed point in a phantom, normalized to the unit photon dose at the isocenter, does not depend on the treatment energy. Measurements with ionization chamber and Monte Carlo simulations were used to evaluate the validity of this hypothesis. DEPS method was compared to already published correction methods, such as the use of neutron absorber materials. In addition to its simplicity, an advantage of DEPs procedure is that it can be applied to any radiotherapy machine. - Highlights: • Correction of thermal neutron detectors for parasitic photon response. • Peripheral photon dose study with distance in high and low energies in radiotherapy environments. • Double energy photon subtraction methodology for reducing photon contribution in any thermal neutron detector.
Availability note (English)
Available from http://dx.doi.org/10.1016/j.apradiso.2016.12.060Additional details
Identifiers
- DOI
- 10.1016/j.apradiso.2016.12.060;
- PII
- S0969-8043(16)30243-3;
Publishing Information
- Journal Title
- Applied Radiation and Isotopes
- Journal Volume
- 123
- Journal Page Range
- p. 32-35
- ISSN
- 0969-8043
- CODEN
- ARISEF
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 48089661
- Subject category
- S07: ISOTOPES AND RADIATION SOURCES; S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ACCELERATORS; COMPARATIVE EVALUATIONS; COMPUTERIZED SIMULATION; CONTAMINATION; CORRECTIONS; IONIZATION CHAMBERS; MONTE CARLO METHOD; NEOPLASMS; NEUTRON ABSORBERS; NEUTRON DETECTORS; NEUTRON FLUENCE; PHANTOMS; PHOTONS; RADIATION DOSES; RADIOTHERAPY; SENSORS; THERMAL NEUTRONS
- Descriptors DEC
- BARYONS; BOSONS; CALCULATION METHODS; DISEASES; DOSES; ELEMENTARY PARTICLES; EVALUATION; FERMIONS; HADRONS; MASSLESS PARTICLES; MEASURING INSTRUMENTS; MEDICINE; MOCKUP; NEUTRONS; NUCLEAR MEDICINE; NUCLEONS; RADIATION DETECTORS; RADIOLOGY; SIMULATION; STRUCTURAL MODELS; THERAPY
Optional Information
- Copyright
- Copyright (c) 2017 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.