Published August 1982
| Version v1
Report
Open
Preventive detection of incipient failure and improvement of availability of French PWR using acoustic emission
Creators
- 1. CGE, 75 - Paris (France)
Description
Laboratory tests, on site experience gained on PWR during start up test as well as during nominal functioning have given FRAMATOME very great confidence in A.E. techniques for preventive detection of incidents. Loose part and leakage monitoring are already being used on an industrial basis. Crack growth detection and monitoring are still in the investigation phase and various. Research and Development programs are presently being carried out
Availability note (English)
MF available from INIS under the Report Number.Files
16010965.pdf
Files
(237.6 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:a6cc3b678b852a204da513188fef96bc
|
237.6 kB | Preview Download |
Additional details
Publishing Information
- Imprint Pagination
- 12 p.
- Report number
- FRA--140-3
Conference
- Title
- 20. World conference on non destructive testing.
- Dates
- 22-28 Aug 1982.
- Place
- Moscow (USSR).
INIS
- Country of Publication
- France
- Country of Input or Organization
- France
- INIS RN
- 16010965
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- ACOUSTIC EMISSION TESTING; CRACK PROPAGATION; FAILED ELEMENT DETECTION; IN-SERVICE INSPECTION; LEAK TESTING; LOOSE PARTS MONITORING; PRESSURE VESSELS; PWR TYPE REACTORS
- Descriptors DEC
- ACOUSTIC TESTING; CONTAINERS; DETECTION; ENRICHED URANIUM REACTORS; INSPECTION; MATERIALS TESTING; MONITORING; NONDESTRUCTIVE TESTING; POWER REACTORS; REACTORS; TESTING; THERMAL REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS
Optional Information
- Notes
- 5 refs.