Published May 2011 | Version v1
Journal article

Use of megavoltage cine-images for studying intra-thoracic motion during radiotherapy for locally advanced lung cancer

  • 1. The Beatson, West of Scotland Cancer Centre, Glasgow (United Kingdom)
  • 2. Department of Radiation Oncology, VU Medical Centre, Amsterdam (Netherlands)

Description

Background and purpose: Use of planning 4-dimensional CT (4DCT) scans often permits use of smaller target volumes for thoracic tumors but this assumes a reproducible pattern of motion during radiotherapy. We compared cranio-caudal (CC) motion on MV cine-images acquired during treatment with that seen on planning 4DCT. Methods and materials: A pre-programmable respiratory motion phantom and a software tool for motion assessment were used to validate the use of MV cine-images for motion detection. MV cine-images acquired in 20 patients with node-positive lung cancer were analyzed using the same software. Intra-fraction CC motion on 6 MV cine-images from each patient was compared with CC motion on their planning 4DCT. Results: Software-based motion measurement on MV cine-images from the phantom corresponded to actual motion. Mean CC motion of primary tumor, carina and hilus on 4DCT was 7.3 mm (range 2-13.8 mm), 6.8 mm (1.8-21.2) and 11.0 mm (4.2-15.1), respectively. Corresponding intra-fraction motion on MV cine was 4.1 mm (0.6-13.6 mm); 2.7 mm (0-10 mm) and 6.0 mm (1.8-14.4 mm), respectively. The tumor, hilus and carina could be tracked in 95%, 88% and 38% of the MV cine-images, respectively. Conclusions: Intra-fraction motion can be reliably measured using MV-cine images from a phantom. Motion discrepancies identified on MV cine-images can identify patients in whom planning 4DCT scans are not representative.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.radonc.2011.05.037

Additional details

Identifiers

DOI
10.1016/j.radonc.2011.05.037;
PII
S0167-8140(11)00230-1;

Publishing Information

Journal Title
Radiotherapy and Oncology
Journal Volume
99
Journal Issue
2
Journal Page Range
p. 155-160
ISSN
0167-8140
CODEN
RAONDT

INIS

Country of Publication
Ireland
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
43064835
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
CAT SCANNING; DETECTION; IMAGES; LUNGS; NEOPLASMS; PATIENTS; PHANTOMS; RADIOTHERAPY
Descriptors DEC
BODY; COMPUTERIZED TOMOGRAPHY; DIAGNOSTIC TECHNIQUES; DISEASES; MEDICINE; MOCKUP; NUCLEAR MEDICINE; ORGANS; RADIOLOGY; RESPIRATORY SYSTEM; STRUCTURAL MODELS; THERAPY; TOMOGRAPHY

Optional Information

Copyright
Copyright (c) 2011 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.