Published April 1, 1999 | Version v1
Journal article

The bias in radiation diagnosis of fluctuating voids

Creators

Description

The error due to void distributions and fluctuations in void fraction determinations in two-phase-flow systems employing radiation beams is shown to be largest when there are fluctuations along and across the beam. However, the error varies in contrasting manner with the dimensions of the void along and across the beam; it increases with the dimension along the beam but decreases with the dimension across the beam. The error also increases with the amplitude of the fluctuation and with other parameters

Additional details

Identifiers

PII
S0969804398000918;

Publishing Information

Journal Title
Applied Radiation and Isotopes
Journal Volume
50
Journal Issue
4
Journal Page Range
p. 773-781
ISSN
0969-8043
CODEN
ARISEF

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
34015138
Subject category
S07: ISOTOPES AND RADIATION SOURCES;
Descriptors DEI
BEAM PROFILES; ERRORS; FLOWMETERS; FLUCTUATIONS; RADIOMETRIC GAGES; TWO-PHASE FLOW; VOID FRACTION
Descriptors DEC
FLUID FLOW; MEASURING INSTRUMENTS; METERS; VARIATIONS

Optional Information