Position on minimum thickness of the flow interior of Candidate Repository Horizons

Description

A linear elastic analysis of the relationship between roof thickness and crown stress of excavated repository openings was conducted to establish a criterion for the minimum thickness of the flow interior required for construction in Candidate Repository Horizons. A value of 80 feet was found adequate for construction and to be compatible with the NWRB Conceptual Design. 3 refs., 3 figs

Availability note (English)

MF available from INIS under the Report Number; OSTI as TI90006224; INIS.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
12 p.
Report number
RHO-BWI-TI--094

Optional Information

Contract/Grant/Project number
Contract AC06-77RL01030