Published November 2008 | Version v1
Journal article

MR elastography of liver fibrosis: preliminary results comparing spin-echo and echo-planar imaging

  • 1. Universite Catholique de Louvain, St-Luc University Hospital, Diagnostic Radiology Unit, Brussels (Belgium)
  • 2. Philips Medical Systems, Best (Netherlands)
  • 3. Universite Paris Diderot, Hopital Lariboisiere, Paris (France)
  • 4. Universite Paris Diderot, Laboratoire Ondes et Acoustique, Ecole Superieure de Physique et de Chimie Industrielles de la Ville de Paris, Paris (France)

Description

The purpose of this study was to prospectively compare the performance of magnetic resonance (MR) elastography using echo-planar and spin-echo imaging for staging of hepatic fibrosis. Twenty-four patients who had liver biopsy for suspicion of chronic liver disease had MR elastography performed with both spin-echo and echo-planar sequences. At histology, the fibrosis stage was assessed according to METAVIR. The data acquisition time was about 20 min using spin-echo, and only 2 min using echo-planar imaging. The hepatic signal-to-noise ratios were similar on both images (22.51 ± 5.37 for spin-echo versus 21.02 ± 4.76 for echo-planar, p = 0.33). The elasticity measurements and the fibrosis stages were strongly correlated. The Spearman correlation coefficients were r = 0.91 (p < 0.01) with spin-echo and r = 0.84 (p < 0.01) with echo-planar sequences. These correlation coefficients did not differ significantly (p 0.17). A strong correlation was also observed between spin-echo and echo-planar elasticity (r = 0.83, p < 0.001), without systematic bias. The results of our study showed that echo-planar imaging substantially decreased the data acquisition time of MR elastography, while maintaining the image quality and diagnostic performance for staging of liver fibrosis. This suggests that echo-planar MR elastography could replace spin-echo MR elastography in clinical practice. (orig.)

Availability note (English)

Available from: http://dx.doi.org/10.1007/s00330-008-1051-5

Additional details

Identifiers

Publishing Information

Journal Title
European Radiology
Journal Volume
18
Journal Issue
11
Journal Page Range
p. 2535-2541
ISSN
0938-7994
CODEN
EURAE3

INIS

Country of Publication
Germany
Country of Input or Organization
Germany
INIS RN
39118889
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
COMPARATIVE EVALUATIONS; FIBROSIS; LIVER; NMR IMAGING; SPIN ECHO
Descriptors DEC
BODY; DIAGNOSTIC TECHNIQUES; DIGESTIVE SYSTEM; EVALUATION; GLANDS; ORGANS; PATHOLOGICAL CHANGES