Scan acquisition parameter optimization for the treatment of moving tumors in radiotherapy
- 1. Service de radiotherapie-physique, centre regional de lutte contre le cancer Leon-Berard, 28, rue Laennec, 69373 Lyon cedex (France)
- 2. Universite Claude-Bernard Lyon I, 43, boulevard du 11-Novembre-1918, 69622 Villeurbanne cedex (France)
- 3. Inserm U630, 7, avenue Jean-Capelle, 69621 Villeurbanne cedex (France)
- 4. Laboratoire Creatis-LRMN, UMR CNRS 5220, 7, avenue Jean-Capelle, 69621 Villeurbanne cedex (France)
Description
Aim of the study. - In the case of lung tumor treatment, to adjust 3D helical computed tomography (CT) acquisition parameters using a dynamic phantom and compare to the theory the volumes of a moving object. Materials and methods. - Three helical CT acquisitions were compared using a Big Bore CT scan: an 'initial' 3D CT scan (constructor parameters), an 'optimized' 3D CT scan which parameters are chosen to obtain an axial slow scan like acquisition and a 4D CT scan. We used a phantom composed by a ball filled with water set on a dynamic platform moving in the antero-posterior or cranio-caudal direction with a 14 mm amplitude and a 4 s period. For each acquisition and modality (static and dynamic), we quantified the ball volume by automatic contouring and we estimated relative errors. Results. - For an antero-posterior displacement, the volume of the moving ball is under estimated by 14.1 % with the 'initial' scan, by 0.2 % with the 'optimized' scan and over estimated by 0.8 % with the averaged 4D scan. For a cranio-caudal displacement, it is under estimated by about 22 % with the 'initial' scan and by about 1 % with the 'optimized' scan and the averaged 4D scan. Conclusion. - Volume measurements performed with the dynamic phantom allowed us to validate the 'optimized' 3D CT scan parameters because it accurately reflects the volume of a moving object. Radiotherapy departments without 4D CT should adapt scan parameters for internal target volume definition. (authors)
Availability note (English)
Available from doi: http://dx.doi.org/10.1016/j.canrad.2010.07.635Additional details
Additional titles
- Original title (French)
- Optimisation des parametres d'acquisition scanographique pour la radiotherapie des tumeurs mobiles
Identifiers
Publishing Information
- Journal Title
- Cancer Radiotherapie
- Journal Volume
- 15
- Journal Issue
- 2
- Journal Page Range
- p. 115-122
- ISSN
- 1278-3218
- CODEN
- CARAFC
INIS
- Country of Publication
- France
- Country of Input or Organization
- France
- INIS RN
- 43007178
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- BRONCHI; CAT SCANNING; CT-GUIDED RADIOTHERAPY; DATA COVARIANCES; IMAGE PROCESSING; PHANTOMS; POSITIONING; RESPIRATION; SPHERES; TUMOR CELLS; VOLUME
- Descriptors DEC
- ANIMAL CELLS; COMPUTERIZED TOMOGRAPHY; DIAGNOSTIC TECHNIQUES; MEDICINE; MOCKUP; NUCLEAR MEDICINE; PROCESSING; RADIOLOGY; RADIOTHERAPY; RESPIRATORY SYSTEM; STRUCTURAL MODELS; THERAPY; TOMOGRAPHY
Optional Information
- Notes