Published May 1988
| Version v1
Journal article
Iopamidol 150 in intra-arterial digital angiography of the peripheral vasculature: A comparative study
- 1. Rome-1 Univ. (Italy). Chair of Radiology 2
- 2. Bracco Industria Chimica S.p.A., Milan (Italy). Contrast Media Medical Dept.
Description
The results of a comparative double-blind clinical trial involving peripheral intra-arterial DSA performed with low iodine iopamidol concentrations (150 and 200 mg. I/ml) are reported. Forty-six patients were examined for vital signs, local (heat and pain sensations) and systemic reactions and monitored throughout the procedure. No untoward effect was observed apart from mild local reactions, which on the other hand did not produce any movement artifacts. Image quality was good to optimal in 98% of the cases. In no case were higher concentrations of contrast medium (cm) needed. No significant differences between the two concentrations of cm used were observed with respect to either contrast ability of tolerability. (orig.)
Additional details
Publishing Information
- Journal Title
- Eur. J. Radiol.
- Journal Volume
- 8
- Journal Issue
- 2
- Series
- Eur. J. Radiol.
- Journal Page Range
- 85-88
- ISSN
- 0720-048X
- CODEN
- EJRAD
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- Germany
- INIS RN
- 19105246
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ACCURACY; BIOMEDICAL RADIOGRAPHY; BLOOD VESSELS; COMPARATIVE EVALUATIONS; DIGITAL SYSTEMS; IMAGES; IOPAMIDOL; LIMBS; PATIENTS; QUANTITY RATIO; SIDE EFFECTS; X-RAY RADIOGRAPHY
- Descriptors DEC
- BODY; BODY AREAS; CARDIOVASCULAR SYSTEM; CONTRAST MEDIA; DIAGNOSTIC TECHNIQUES; EVALUATION; MEDICINE; ORGANS