Published October 1994 | Version v1
Report

Detection of pump degradation

Creators

  • 1. Oak Ridge National Lab., TN (United States)

Description

There are a variety of stressors that can affect the operation of centrifugal pumps. These can generally be classified as: Mechanical; Hydraulic; Tribological; Chemical; and Other (including those associated with the pump driver). Although these general stressors are active in essentially all centrifugal pumps, the stressor level and the extent of wear and degradation can vary greatly. Parameters that affect the extent of stressor activity are manifold. In order to assure the long-term operational readiness of a pump, it is important to both understand the nature and magnitude of the specific degradation mechanisms and to monitor the performance of the pump

Additional details

Publishing Information

Imprint Title
Transactions of the twenty-second water reactor safety information meeting
Imprint Pagination
129 p.
Journal Page Range
p. 55.
Report number
NUREG/CP--0139

Conference

Title
22. water reactor safety information meeting.
Dates
24-26 Oct 1994.
Place
Bethesda, MD (United States).

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
26067090
Subject category
S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS; S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS; S22: GENERAL STUDIES OF NUCLEAR REACTORS;
Resource subtype / Literary indicator
Conference
Descriptors DEI
CENTRIFUGAL PUMPS; DETECTION; MECHANICAL VIBRATIONS; MONITORING; NUCLEAR POWER PLANTS; REACTOR COMPONENTS; REACTOR SAFETY
Descriptors DEC
EQUIPMENT; NUCLEAR FACILITIES; POWER PLANTS; PUMPS; SAFETY; THERMAL POWER PLANTS