Published October 1994
| Version v1
Report
Detection of pump degradation
Description
There are a variety of stressors that can affect the operation of centrifugal pumps. These can generally be classified as: Mechanical; Hydraulic; Tribological; Chemical; and Other (including those associated with the pump driver). Although these general stressors are active in essentially all centrifugal pumps, the stressor level and the extent of wear and degradation can vary greatly. Parameters that affect the extent of stressor activity are manifold. In order to assure the long-term operational readiness of a pump, it is important to both understand the nature and magnitude of the specific degradation mechanisms and to monitor the performance of the pump
Additional details
Publishing Information
- Imprint Title
- Transactions of the twenty-second water reactor safety information meeting
- Imprint Pagination
- 129 p.
- Journal Page Range
- p. 55.
- Report number
- NUREG/CP--0139
Conference
- Title
- 22. water reactor safety information meeting.
- Dates
- 24-26 Oct 1994.
- Place
- Bethesda, MD (United States).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 26067090
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS; S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS; S22: GENERAL STUDIES OF NUCLEAR REACTORS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- CENTRIFUGAL PUMPS; DETECTION; MECHANICAL VIBRATIONS; MONITORING; NUCLEAR POWER PLANTS; REACTOR COMPONENTS; REACTOR SAFETY
- Descriptors DEC
- EQUIPMENT; NUCLEAR FACILITIES; POWER PLANTS; PUMPS; SAFETY; THERMAL POWER PLANTS