Published 1997
| Version v1
Journal article
Return to service following steam generator chemical cleaning
Creators
- 1. Southern California Edison Co., San Clemente, CA (United States)
- 2. JLS Engineering, Seal Beach, CA (United States)
Description
The purpose of this technical paper is to discuss San Onofre's experience from a chemistry standpoint during the startup of the secondary cycle following the chemical cleaning of steam generators. In addition, a startup strategy is presented, where lessons learned from the unit 2 startup were incorporated into that for unit 3
Additional details
Publishing Information
- Journal Title
- Transactions of the American Nuclear Society
- Journal Volume
- 77
- Journal Page Range
- p. 294.
- ISSN
- 0003-018X
- CODEN
- TANSAO
Conference
- Title
- 1997 American Nuclear Society (ANS) winter meeting.
- Dates
- 16-20 Nov 1997.
- Place
- Albuquerque, NM (United States).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 29021057
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- CLEANING; CORROSION; DEPOSITS; REACTOR START-UP; SAN ONOFRE-2 REACTOR; SAN ONOFRE-3 REACTOR; STEAM; STEAM GENERATORS; TUBES
- Descriptors DEC
- BOILERS; CHEMICAL REACTIONS; ENRICHED URANIUM REACTORS; POWER REACTORS; PWR TYPE REACTORS; REACTORS; START-UP; THERMAL REACTORS; VAPOR GENERATORS; WATER COOLED REACTORS; WATER MODERATED REACTORS
Optional Information
- Secondary number(s)
- CONF-971125--.