Neutron flux calculation for central channel in first cycle of SPRR-300
Creators
- 1. Institute of Nuclear Physics and Chemistry, CAEP, Mianyang (China)
Description
The physical model of the 300# swimming pool research reactor (SPRR-300) based on the Monte Carlo codeMCNP has been verified. Sophisticated modeling is conducted. An effective multiplication factor value of 1.00229 is obtained, existing a relative error of 0.229% compared with the critical value. Meanwhile, a problem comes out that the interrupt and continue-run with parallel version of MCNP doesn't work. The problem is solved through trail and error process. A reasonable application of flux tally average over a cell and flux tally at a point is suggested, namely the former is prior to the latter to tally in big volume. Comparison between calculation results and experimental data shows that the thermal neutron flux has a deviation of 4.6% at a power level of 3 MW. That is to say, the calculated value and the experimental value agree well with each other, and the neutron flux result is dependable. (authors)
Additional details
Publishing Information
- Journal Title
- High Power Laser and Particle Beams
- Journal Volume
- 24
- Journal Issue
- 12
- Journal Page Range
- p. 3001-3005
- ISSN
- 1001-4322
INIS
- Country of Publication
- China
- Country of Input or Organization
- China
- INIS RN
- 45093631
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Descriptors DEI
- CHINA; COMPARATIVE EVALUATIONS; ERRORS; MONTE CARLO METHOD; MULTIPLICATION FACTORS; NEUTRON FLUX; POOL TYPE REACTORS; RESEARCH REACTORS; SIMULATION; THERMAL NEUTRONS
- Descriptors DEC
- ASIA; BARYONS; CALCULATION METHODS; DIMENSIONLESS NUMBERS; ELEMENTARY PARTICLES; EVALUATION; FERMIONS; HADRONS; NEUTRONS; NUCLEONS; RADIATION FLUX; REACTORS; RESEARCH AND TEST REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS
Optional Information
- Notes
- 3 figs., 1 tabs., 9 refs.