Intercomparison of gamma ray scattering and transmission techniques for fluid–fluid and fluid–air interface levels detection and density measurements
Creators
- 1. Radiological Safety Division, Indira Gandhi Centre for Atomic Research, Kalpakkam 603102, TN (India)
Description
This paper focuses on the fluid–fluid, fluid–air interface level detection and density determination by gamma scattering method and intercomparison with transmission (gammatography) technique. The Monte Carlo (MC) numerical simulation of the scattering phenomena is done using the MCNP code. The obtained accuracies and resolution of the level detections and density measurements are higher in case of gamma scattering method compared to transmission method. - Highlights: ► A gamma scattering method for fluid–fluid interface level measurement is described. ► Results are compared with those obtained by transmission method. ► Density resolution of scattering method is higher by a factor of 3.43. ► Measured interface level accuracy obtained is higher in scattering method.
Availability note (English)
Available from http://dx.doi.org/10.1016/j.apradiso.2011.10.019Additional details
Identifiers
- DOI
- 10.1016/j.apradiso.2011.10.019;
- PII
- S0969-8043(11)00534-3;
Publishing Information
- Journal Title
- Applied Radiation and Isotopes
- Journal Volume
- 70
- Journal Issue
- 3
- Journal Page Range
- p. 462-469
- ISSN
- 0969-8043
- CODEN
- ARISEF
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 43072935
- Subject category
- S07: ISOTOPES AND RADIATION SOURCES;
- Descriptors DEI
- ACCURACY; AIR; COMPUTERIZED SIMULATION; FLUIDS; GAMMA RADIATION; INTERFACES; MONTE CARLO METHOD; RADIATION DETECTION; SCATTERING
- Descriptors DEC
- CALCULATION METHODS; DETECTION; ELECTROMAGNETIC RADIATION; FLUIDS; GASES; IONIZING RADIATIONS; RADIATIONS; SIMULATION
Optional Information
- Copyright
- Copyright (c) 2011 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.