Published September 1, 2010 | Version v1
Journal article

Impact of Volumetric Modulated Arc Therapy Technique on Treatment With Partial Breast Irradiation

  • 1. Department of Radiation Therapy, Fudan University Cancer Hospital, Shanghai (China)
  • 2. Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina (United States)

Description

Purpose: To investigate the technical feasibility of volumetric modulated arc therapy (V-MAT) in the delivery of partial breast irradiation (PBI). Methods and Materials: V-MAT and the standard, three-dimensional conformal radiotherapy (3D-CRT), were compared retrospectively in 8 patients previously treated with PBI. These patients' plans were replanned with a single partial arc using V-MAT that included partial blocking to minimize normal tissue dose. Dosimetric parameters were calculated to evaluate plan quality. Quality assurance studies included verifying both the point and the multiple planar doses. Total monitor units and delivery time were also evaluated, and collision clearance was analyzed. Results: Volumes of ipsilateral lung irradiated to 10 Gy (V10) and 20 Gy (V20) by V-MAT were significantly less than those of 3D-CRT (p = 0.03 for V10 and p = 0.025 for V20). The volume of ipsilateral breast irradiated to 5 Gy was significantly less by using V-MAT than with 3D-CRT (p = 0.02), with a ratio of integrated dose of <1.00. The total mean monitor units (489 ± 38) for V-MAT were significantly less than those for 3D-CRT (634 ± 123) (p = 0.017), with a 23% reduction. The average machine delivery time was 1.21 ± 0.10 min for the V-MAT plans and 6.28 ± 1.40 min for the 3D-CRT plans, resulting in a reduction factor of 80.1%. The conformity indexes were 1.3 in the V-MAT plans and 1.5 in the 3D-CRT plans (p = 0.102). Conclusions: V-MAT technology is feasible for PBI patients. Compared to a conventional 3D-CRT technique, it is more efficient, offers equivalent or better dose conformity, delivers lower doses to the ipsilateral lung and breast, and may potentially reduce intrafractional motion.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.ijrobp.2009.10.036

Additional details

Identifiers

DOI
10.1016/j.ijrobp.2009.10.036;
PII
S0360-3016(09)03429-4;

Publishing Information

Journal Title
International Journal of Radiation Oncology, Biology and Physics
Journal Volume
78
Journal Issue
1
Journal Page Range
p. 288-296
ISSN
0360-3016
CODEN
IOBPD3

INIS

Country of Publication
United States
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
42031685
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
LUNGS; MAMMARY GLANDS; RADIATION DOSES; RADIOTHERAPY; THREE-DIMENSIONAL CALCULATIONS
Descriptors DEC
BODY; DOSES; GLANDS; MEDICINE; NUCLEAR MEDICINE; ORGANS; RADIOLOGY; RESPIRATORY SYSTEM; THERAPY

Optional Information

Copyright