Published February 1986 | Version v1
Report Open

Quality control procedures for iodinated radiopharmaceuticals 131I-Hippuran and 131I-Risa

Description

A rapid miniaturized chromatography system was developed for fast determination of the proportion of inorganic radioactive iodide from radiopharmaceutical 131I-Hippuran and 131I-Risa. The technical parameters associated with miniaturized chromatography system were evaluated. One of the problems found in this system was the movement of the 131I-Risa from the origin with consequent overestimation of the inorganic iodide. A correct spot placement eliminated this problem. (Author)

Availability note (English)

MF available from INIS under the Report Number.

Abstract (Portuguese)

Desenvolveu-se um sistema de cromatografia miniaturizada para determinacao rapida da proporcao de iodeto inorganico radioativo nos radiofarmacos Hippuran 131I e Risa 131I. Avaliaram-se os parametros tecnicos associados com o sistema cromatografico miniaturizado. Um dos problemas encontrados neste sistema foi o deslocamento da Risa 131 a partir da origem com consequente erro na determinacao do iodeto inorganico. Uma aplicacao correta da amostra elimina estre problema. (Autor)

Files

18008294.pdf

Files (165.8 kB)

Name Size Download all
md5:d84c45832051b770e5a467de1f84140b
165.8 kB Preview Download

Additional details

Additional titles

Original title (Portuguese)
Procedimentos para controle de qualidade dos radiofarmacos Hippuram

Publishing Information

Imprint Pagination
9 p.
Report number
IPEN-PUB--97