Computer aided collimation gamma (Cacao): a new approach in measuring and visualizing the distribution of X and gamma ray emitters in contaminate wounds
- 1. Hopital Pitie-Salpetriere (LENA), 75 - Paris (France)
- 2. Centre Hospitalier Universitaire de Larrey, Service de Medecine Nucleaire, 49 - Angers (France)
- 3. Institut de Radioprotection et de Surete Nucleaire, IRSN, Dept. de Protection de la Sante de l'Homme et de Dosimetrie, 92 - Fontenay aux Roses (France)
- 4. Faculte des Sciences d'Orsay (LPS), 91 - Orsay (France)
Description
The treatment of contaminated wounds can be greatly improved by visualizing the distribution of the radioactivity that is present. The low sensitivity of the conventional Anger camera means that it can only be used where there is a high level of activity. Moreover, these gamma cameras cannot make full use of the recent progress made in high spatial resolution semi-conductor detectors. In order to increase sensitivity while at the same time maintaining a sufficient resolution of the reconstructed image, the principle of the Computer aided collimation gamma camera (CACAO in French) was proposed as a possible means of using gamma cameras in intern dosimetry. This principle is based on the combined use of collimators with holes that are wider- than the intrinsic resolution of the detector, circular and linear scanning movements, a detector sensitive to the source depth and a specific reconstruction algorithm. This article presents the recent developments of the CACAO system and illustrates by a theoretical and experimental study, its performances compared with the classic tomography system. We start with a general overview of the CACAO system and its reconstruction algorithm. First of all, the superiority of the CACAO system is demonstrated by a simulation ,study. Then, an experimental bench was developed using an implanted silicon pixel detector specifically designed to allow the visualization of a subject contaminated with low energy X and gamma emitters. The study presented here shows images obtained from a phantom composed of three sources of Americium 341Am. Although the comparison between the conventional and CACAO approaches were not carried out with optimal parameters, especially for CACAO, the initial results show that CACAO has an improved sensitivity and a superior resolution. Finally, the transposition of this system to the practical study of contaminated wounds is discussed. (authors)
Additional details
Additional titles
- Original title (French)
- Cacao (camera a collimation assistee par ordinateur): une nouvelle approche pour reconstruire et visualiser des contaminations d'emetteurs X et gamma dans les blessures
Publishing Information
- Journal Title
- Bulletin du Bureau National de Metrologie
- Journal Volume
- 2003-2
- Journal Issue
- no.123
- Journal Page Range
- p. 119-130
- ISSN
- 0982-2232
- CODEN
- BBNMEN
Conference
- Title
- X and gamma ray spectrometry days
- Original Conference Title
- Journees de spectrometrie gamma et X
- Dates
- 15-17 Oct 2002
- Place
- Saclay (France)
INIS
- Country of Publication
- France
- Country of Input or Organization
- France
- INIS RN
- 35027029
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- AMERICIUM 241; CONTAMINATION; GAMMA CAMERAS; PHANTOMS; SENSITIVITY
- Descriptors DEC
- ACTINIDE NUCLEI; ALPHA DECAY RADIOISOTOPES; AMERICIUM ISOTOPES; CAMERAS; HEAVY NUCLEI; ISOTOPES; MOCKUP; NUCLEI; ODD-EVEN NUCLEI; RADIOISOTOPES; SPONTANEOUS FISSION RADIOISOTOPES; STRUCTURAL MODELS; YEARS LIVING RADIOISOTOPES
Optional Information
- Notes
- 49 refs.