Published May 1995
| Version v1
Report
Static and seismic calculation of the TC 10 continuous coolant purification piping
Description
A complete static and seismic calculation was performed within the integrity assessment of the continuous coolant purification piping at the Temelin NPP. The model involved the pipe segment between the main circulation loop and the mechanical filter. Based on the results, reinforcement of each route with two VES 10 viscous dampers was proposed. 12 tabs., 3 figs., 3 refs
Availability note (English)
Available from Ustav jaderneho vyzkumu Rez a.s., 250 68 Rez, Czech Republic.Additional details
Additional titles
- Original title (Czech)
- Staticky a sesmicky vypocet potrubi kontinuelniho cisteni chladiva TC 10
- Augmented title (English)
- Temelin NPP
Publishing Information
- Imprint Pagination
- [31 p.].
- Report number
- UJV--10460-T
INIS
- Country of Publication
- Czech Republic
- Country of Input or Organization
- Czech Republic
- INIS RN
- 28021812
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Resource subtype / Literary indicator
- Numerical Data, Non-conventional Literature
- Descriptors DEI
- COOLANTS; PIPES; SEISMIC EFFECTS; SEISMIC ISOLATION; SHOCK ABSORBERS; STRESS ANALYSIS; TEMELIN-1 REACTOR; THEORETICAL DATA
- Descriptors DEC
- DATA; ENRICHED URANIUM REACTORS; INFORMATION; NUMERICAL DATA; POWER REACTORS; PWR TYPE REACTORS; REACTORS; THERMAL REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS; WWER TYPE REACTORS