Static and seismic calculation of the TC 10 continuous coolant purification piping

Description

A complete static and seismic calculation was performed within the integrity assessment of the continuous coolant purification piping at the Temelin NPP. The model involved the pipe segment between the main circulation loop and the mechanical filter. Based on the results, reinforcement of each route with two VES 10 viscous dampers was proposed. 12 tabs., 3 figs., 3 refs

Availability note (English)

Available from Ustav jaderneho vyzkumu Rez a.s., 250 68 Rez, Czech Republic.

Additional details

Additional titles

Original title (Czech)
Staticky a sesmicky vypocet potrubi kontinuelniho cisteni chladiva TC 10
Augmented title (English)
Temelin NPP

Publishing Information

Imprint Pagination
[31 p.].
Report number
UJV--10460-T

INIS

Country of Publication
Czech Republic
Country of Input or Organization
Czech Republic
INIS RN
28021812
Subject category
S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
Resource subtype / Literary indicator
Numerical Data, Non-conventional Literature
Descriptors DEI
COOLANTS; PIPES; SEISMIC EFFECTS; SEISMIC ISOLATION; SHOCK ABSORBERS; STRESS ANALYSIS; TEMELIN-1 REACTOR; THEORETICAL DATA
Descriptors DEC
DATA; ENRICHED URANIUM REACTORS; INFORMATION; NUMERICAL DATA; POWER REACTORS; PWR TYPE REACTORS; REACTORS; THERMAL REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS; WWER TYPE REACTORS