New cryogenic test station at CERN for superconducting magnets and their components
- 1. CERN, Geneva (Switzerland)
Description
Following the optimization planning of the superconducting magnet test facilities at CERN, a new station for vertical test of R and D magnets has been installed in a building previously dedicated to horizontal test of long superconducting magnets built for the LHC. This paper describes the main cryogenic and powering characteristics of the new test station. It gives the details of all 4 cryostats and the related equipment that composes the test station. Although the test station is optimized for low temperature superconducting magnet tests, it offers a wide range of possibilities for testing cold powering devices and components of magnets and accelerators in a temperature range from 1.8 K to 50 K. The cryostat for magnets up to 1 m diameter and 2.5 m long will complete the test station in 2013. (author)
Additional details
Identifiers
Publishing Information
- Imprint Title
- ICEC 24 - ICMC 2012: Proceedings of 24th international cryogenic engineering conference and international cryogenic materials conference 2012
- Imprint Pagination
- 932 p.
- Journal Page Range
- p. 299-302
Conference
- Title
- 24. international cryogenic engineering conference; ICMC 2012: International cryogenic materials conference 2012
- Acronym
- ICEC 24
- Dates
- 14-18 May 2012
- Place
- Fukuoka (Japan)
INIS
- Country of Publication
- Japan
- Country of Input or Organization
- Japan
- INIS RN
- 46060310
- Subject category
- S43: PARTICLE ACCELERATORS;
- Resource subtype / Literary indicator
- Conference, Non-conventional Literature
- Descriptors DEI
- CERN LHC; CRYOGENICS; CRYOSTATS; INSTALLATION; OPERATION; OPTIMIZATION; PERFORMANCE TESTING; SUPERCONDUCTING MAGNETS; TEMPERATURE RANGE 0013-0065 K; TEST FACILITIES
- Descriptors DEC
- ACCELERATORS; CONTROL EQUIPMENT; CYCLIC ACCELERATORS; ELECTRICAL EQUIPMENT; ELECTROMAGNETS; EQUIPMENT; MAGNETS; STORAGE RINGS; SUPERCONDUCTING DEVICES; SYNCHROTRONS; TEMPERATURE RANGE; TESTING; THERMOSTATS
Optional Information
- Notes
- 3 refs., 4 figs., 1 tab.