Published 1995 | Version v1
Miscellaneous

Electron beam sterilization of medical products. The effects of irradiation on surgical rubber gloves

  • 1. Malaysian Institute for Nuclear Technology Research (MINT), Bangi (Malaysia). Radiation Processing Technology Div.
  • 2. Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment

Description

Radiation damage of five commercially produced rubber gloves using electron beam and γ- rays from Cobalt-60 have been investigated in relation to radiation sterilization. Samples were irraadiated up to 100 kGy. The radiation damage of rubber gloves was ssmaller in electron beam than γ- rays. Good retention in tensile strength (T sub b) and elongation at break (E sub b) were observed even after six months storage. Higher beam currents (higher dose rate) above 5 mA was favourable for sterilization of rubber gloves because of smaller degradation. The tensile strength and elongation of the irradiated rubber gloves is still withinAM/N

Part of:
Compilation of research papers 1994

Additional details

Publishing Information

Imprint Title
Compilation of research papers 1994
Imprint Pagination
671 p.
Journal Page Range
p. 19-31.
Report number
INIS-mf--14786

Optional Information