Value of a noise-optimized virtual monoenergetic reconstruction technique in dual-energy CT for planning of transcatheter aortic valve replacement
Creators
- 1. University Hospital Frankfurt, Department of Diagnostic and Interventional Radiology, Frankfurt (Germany)
Description
To evaluate objective and subjective image quality of a noise-optimized virtual monoenergetic imaging (VMI+) reconstruction technique in dual-energy computed tomography (DECT) angiography prior to transcatheter aortic valve replacement (TAVR). Datasets of 47 patients (35 men; 64.1 ± 10.9 years) who underwent DECT angiography of heart and vascular access prior to TAVR were reconstructed with standard linear blending (F0.5), VMI+, and traditional monoenergetic (VMI) algorithms in 10-keV intervals from 40-100 keV. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of 564 arterial segments were evaluated. Subjective analysis was rated by three blinded observers using a Likert scale. Mean SNR and CNR were highest in 40 keV VMI+ series (SNR, 27.8 ± 13.0; CNR, 26.3 ± 12.7), significantly (all p < 0.001) superior to all VMI series, which showed highest values at 70 keV (SNR, 18.5 ± 7.6; CNR, 16.0 ± 7.4), as well as linearly-blended F0.5 series (SNR, 16.8 ± 7.3; CNR, 13.6 ± 6.9). Highest subjective image quality scores were observed for 40, 50, and 60 keV VMI+ reconstructions (all p > 0.05), significantly superior to all VMI and standard linearly-blended images (all p < 0.01). Low-keV VMI+ reconstructions significantly increase CNR and SNR compared to VMI and standard linear-blending image reconstruction and improve subjective image quality in preprocedural DECT angiography in the context of TAVR planning. (orig.)
Availability note (English)
Available from: http://dx.doi.org/10.1007/s00330-016-4422-3Additional details
Identifiers
Publishing Information
- Journal Title
- European Radiology
- Journal Volume
- 27
- Journal Issue
- 2
- Journal Page Range
- p. 705-714
- ISSN
- 0938-7994
- CODEN
- EURAE3
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 48030171
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ALGORITHMS; AORTA; BLOOD CIRCULATION; BLOOD FLOW; COMPARATIVE EVALUATIONS; COMPUTERIZED TOMOGRAPHY; CONTRAST MEDIA; HEART; IMAGE PROCESSING; IMPLANTS; KEV RANGE 10-100; NOISE; SURGERY; SURGICAL MATERIALS; VALVES
- Descriptors DEC
- ARTERIES; BLOOD VESSELS; BODY; CARDIOVASCULAR SYSTEM; CONTROL EQUIPMENT; DIAGNOSTIC TECHNIQUES; ENERGY RANGE; EQUIPMENT; EVALUATION; FLOW REGULATORS; KEV RANGE; MATERIALS; MATHEMATICAL LOGIC; MEDICAL SUPPLIES; MEDICINE; ORGANS; PROCESSING; TOMOGRAPHY