Published October 2008 | Version v1
Journal article

A spatially resolved ion temperature diagnostic for the National Ignition Facility

  • 1. Los Alamos National Laboratory, P.O. Box 1663, Los Alamos, New Mexico 87545 (United States)
  • 2. National Security Technology, 3000 East Gate, Los Alamos, New Mexico 87544 (United States)

Description

The concepts and initial development efforts for a spatially resolved ion temperature diagnostic are described. The diagnostic is intended for Inertial Confinement Fusion experiments at the National Ignition Facility and is an integration of neutron aperture imaging and ion temperature techniques. The neutron imaging technique is extended by recording tomographic projections of the radiation-to-light converter on a streak camera. The streak record is used to calculate images at multiple times during the arrival of the thermally broadened 14.1 MeV neutron flux. The resulting set of images is used to determine the spatially resolved ion temperature.

Additional details

Identifiers

Publishing Information

Journal Title
Review of Scientific Instruments
Journal Volume
79
Journal Issue
10
Journal Page Range
p. 10E537-10E537.3
ISSN
0034-6748
CODEN
RSINAK

Optional Information

Notes
(c) 2008 American Institute of Physics