Cone penetrometer testing and discrete-depth groundwater sampling techniques: A cost-effective method of site characterization in a multiple-aquifer setting
Creators
- 1. Geomatrix Consultants, Inc., San Francisco, CA (United States)
Description
Cone penetrometer testing (CPT), combined with discrete-depth groundwater sampling methods, can reduce significantly the time and expense required to characterize large sites that have multiple aquifers. Results from the screening site characterization can be used to design and install a cost-effective monitoring well network. At a site in northern California, it was necessary to characterize the stratigraphy and the distribution of volatile organic compounds (VOCs) to a depth of 80 feet within a 1/2 mile-by-1/4-mile residential and commercial area in a complex alluvial fan setting. To expedite site characterization, a five-week field screening program was implemented that consisted of a shallow groundwater survey, CPT soundings, and discrete-depth groundwater sampling. Based on continuous lithologic information provided by the CPT soundings, four coarse-grained water-yielding sedimentary packages were identified. Eighty-three discrete-depth groundwater samples were collected using shallow groundwater survey techniques, the BAT Enviroprobe, or the QED HydroPunch 1, depending on subsurface conditions. A 20-well monitoring network was designed and installed to monitor critical points within each sedimentary package. Understanding the vertical VOC distribution and concentrations produced substantial cost savings by minimizing the number of permanent monitoring wells and reducing the number of costly conductor casings to be installed. Significant long-term cost savings will result from reduced sampling costs. Where total VOC concentrations exceeded 20 φg/l in the screening samples, a good correlation was found between the discrete-depth screening data and data from monitoring wells. Using a screening program to characterize the site before installing monitoring wells resulted in an estimated 50-percent reduction in costs for site characterization, 65-percent reduction in time for site characterization, and 50-percent reduction in long-term monitoring costs
Additional details
Publishing Information
- Publisher
- Ground Water Management.
- Imprint Place
- Dublin, OH (United States)
- Imprint Title
- Sixth national outdoor action conference on aquifer restoration, ground water monitoring and geophysical methods
- Imprint Pagination
- 784 p.
- Journal Page Range
- p. 299-313.
Conference
- Title
- 6. national outdoor action conference on aquifer restoration, ground water monitoring and geophysical methods.
- Dates
- 11-13 May 1992.
- Place
- Las Vegas, NV (United States).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 24053278
- Subject category
- S58: GEOSCIENCES; S54: ENVIRONMENTAL SCIENCES; S54: ENVIRONMENTAL SCIENCES;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- AQUIFERS; CALIFORNIA; COST; EVALUATION; GROUND WATER; MONITORING; ORGANIC COMPOUNDS; REMEDIAL ACTION; SAMPLERS; SITE CHARACTERIZATION; STRATIGRAPHY; VOLATILE MATTER; WELLS
- Descriptors DEC
- DEVELOPED COUNTRIES; EQUIPMENT; HYDROGEN COMPOUNDS; LABORATORY EQUIPMENT; MATTER; NORTH AMERICA; OXYGEN COMPOUNDS; USA; WATER
Optional Information
- Secondary number(s)
- CONF-9205103--.