Published September 30, 1988 | Version v1
Journal article

Conceptual design of the vaccum system for the 6 GeV storage ring

  • 1. RIKEN (The Institute of Physical and Chemical Research 2--1, Hirosawa, Wako-Shi, Saitama, 351--01, Japan)

Description

Preliminary design results for the vacuum system of the 6 GeV storage ring which is being planned at RIKEN, are presented. The vacuum system is designed to maintain a beam-on operating pressure of 1 x 10/sup 10/ Torr. This report places special emphasis on the new vacuum chamber whose antechamber is with two isolated-pump chambers, and pumping system. The distribution of the synchrotron radiation depositions at the absorber or within the vacuum chambers is discussed. Finally the new type of a crotch absorber is briefly described

Additional details

Publishing Information

Journal Title
AIP Conference Proceedings
Journal Volume
171
Journal Issue
1
Series
AIP Conf. Proc.
Journal Page Range
73-80
ISSN
0094-243X
CODEN
APCPC

Conference

Title
Topical conference on vacuum design of advanced and compact synchrotron light sources.
Dates
16-18 May 1988.
Place
Upton, NY (USA).

Optional Information

Secondary number(s)
CONF-880552--.