Published 1990 | Version v1
Book

Study of MWPCs with interpolating pad readout for high multiplicity charged particle detection

Description

Two types of MWPC with interpolating cathode pad readout for two dimensional position sensitive detection have been studied. One type uses rectangular pads and resistive charge division. A detector with an active area of 26cm x 16cm, over 1,000 readout channels has been built. With readout spacing of 1 cm, a position resolution of ∼ 70μm (rms) for 5.4 keV X-rays and a differential non-linearity of ±6% have been achieved. Another type of detector uses chevron shaped pads for geometrical charge division. Position resolution ∼ 50μm (rms) for 5.4 keV X-rays has been observed in a test detector and results of an investigation to reduce differential non-linearity are reported

Additional details

Publishing Information

Publisher
World Scientific Publishing Co. Pte. Ltd.
Imprint Place
Teaneck, NJ (United States)
Imprint Title
Detector research and development for the superconducting super collider: Proceedings
Imprint Pagination
817 p.
Journal Page Range
p. 205-208.

Conference

Title
Symposium on detector research and development for the Superconducting Super Collider.
Dates
15-18 Oct 1990.
Place