Published 1999 | Version v1
Book

Exposure control strategy adopted during refurbishment of Rajasthan Atomic Power Station, Unit-2

  • 1. Health Physics Unit, RAPS, Health Physics Div., Bhabha Atomic Research Centre, Mumbai (India)

Description

Rajasthan Atomic Power Station (RAPS) consists of two units of 220 MWe PHWR type of reactors having 306 horizontal coolant channels. The en masse coolant channel replacement (EMCCR) of RAPS-2 was a unique operation done on any Indian PHWR. Highly active in-core components removed were effectively contained in shielding flasks and disposed off at Solid Waste Management Plant (SWAMP). In view of very high intensity of non-uniform radiation field emanating from the channels, control of external exposures to the working personnel became the main focus of attraction during the entire campaign. Mock-up facilities were established and workers were trained and qualified for working in high active areas

Part of:
Proceedings of the twenty fourth IARP conference on radiation protection in nuclear fuel cycle: control of occupational and public exposures

Additional details

Publishing Information

Publisher
Indian Association for Radiation Protection
Imprint Place
Mumbai (India)
Imprint Title
Proceedings of the twenty fourth IARP conference on radiation protection in nuclear fuel cycle: control of occupational and public exposures
Imprint Pagination
326 p.
Journal Page Range
p. 63-70

Conference

Title
control of occupational and public exposures
Acronym
24. IARP conference on radiation protection in nuclear fuel cycle
Dates
20-22 Jan 1999
Place
Kakrapar (India)

Optional Information

Notes
4 figs., 2 tabs.