Stimulated-echo diffusion-weighted imaging with moderate b values for the detection of prostate cancer
Creators
- 1. Department of Radiology, School of Medicine and Public Health, University of Wisconsin Madison, WI (United States)
- 2. Department of Medical Physics, University of Wisconsin Madison, WI (United States)
Description
Conventional spin-echo (SE) DWI leads to a fundamental trade-off depending on the b value: high b value provides better lesion contrast-to-noise ratio (CNR) by sacrificing signal-to-noise ratio (SNR), image quality, and quantitative reliability. A stimulated-echo (STE) DWI acquisition is evaluated for high-CNR imaging of prostate cancer while maintaining SNR and reliable apparent diffusion coefficient (ADC) mapping. In this prospective, IRB-approved study, 27 patients with suspected prostate cancer (PCa) were scanned with three DWI sequences (SE b = 800 s/mm, SE b = 1500 s/mm, and STE b = 800 s/mm) after informed consent was obtained. ROIs were drawn on biopsy-confirmed cancer and non-cancerous tissue to perform quantitative SNR, CNR, and ADC measurements. Qualitative metrics (SNR, CNR, and overall image quality) were evaluated by three experienced radiologists. Metrics were compared pairwise between the three acquisitions using a t test (quantitative metrics) and Wilcoxon rank test (qualitative metrics). Quantitative measurements showed that STE DWI at b = 800 s/mm has significantly better SNR compared to SE DWI at b = 1500 s/mm (p < 0.0001) and comparable CNR to high-b value SE DWI at b = 1500 s/mm (p < 0.05) in the peripheral zone. Qualitative assessment showed preference to STE b = 800 s/mm in SNR and SE b = 1500 s/mm in CNR. The overall image quality and lesion detectability among most readers showed no significant preference between STE b = 800 s/mm and SE b = 1500 s/mm. Further, STE DWI had similar ADC contrast between lesion and normal tissue as SE DWI at b = 800 s/mm (p = 0.90). STE DWI has the potential to provide high-SNR, high-CNR imaging of prostate cancer while also enabling reliable ADC mapping.
Availability note (English)
Available from: http://dx.doi.org/10.1007/s00330-020-06689-wAdditional details
Identifiers
Publishing Information
- Journal Title
- European Radiology
- Journal Volume
- 30
- Journal Issue
- 6
- Journal Page Range
- p. 3236-3244
- ISSN
- 0938-7994
- CODEN
- EURAE3
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 51080131
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- BIOPSY; CARCINOMAS; COMPARATIVE EVALUATIONS; DETECTION; DIFFUSION; IMAGE PROCESSING; MAPPING; METRICS; NMR IMAGING; PROSTATE; RELAXATION TIME; RELIABILITY; SIGNAL-TO-NOISE RATIO; SPATIAL RESOLUTION; SPIN ECHO; WEIGHTING FUNCTIONS
- Descriptors DEC
- BODY; DIAGNOSTIC TECHNIQUES; DIMENSIONLESS NUMBERS; DISEASES; EVALUATION; FUNCTIONS; GLANDS; MALE GENITALS; NEOPLASMS; ORGANS; PROCESSING; RESOLUTION