Published December 1999 | Version v1
Book

Absolute position read back for stripper foil at terminal

  • 1. Nuclear Science Centre, New Delhi (India)

Description

15 UD pelletron accelerator at Nuclear Science Centre, New Delhi, uses two types of stripper at high voltage terminal-those are gas stripper and foil stripper. Gas stripper is generally used for heavy ions and foil stripper for light ions. Stripping efficiency depends upon the health of stripper foil used. It is very important to ensure the condition of stripper foil in use is good for smooth operation of accelerator

Part of:
DAE symposium on nuclear physics: contributed papers. V. 42B

Additional details

Publishing Information

Publisher
Bhabha Atomic Research Centre
Imprint Place
Mumbai (India)
Imprint Title
DAE symposium on nuclear physics: contributed papers. V. 42B
Imprint Pagination
505 p.
Journal Page Range
p. 370-371

Conference

Title
DAE symposium on nuclear physics
Dates
27-31 Dec 1999
Place
Chandigarh (India)

INIS

Country of Publication
India
Country of Input or Organization
India
INIS RN
32010150
Subject category
S43: PARTICLE ACCELERATORS;
Resource subtype / Literary indicator
Conference
Descriptors DEI
ANALOG SYSTEMS; BEAM STRIPPERS; COMPUTERIZED CONTROL SYSTEMS; ELECTRIC POTENTIAL; PELLETRON ACCELERATORS; READOUT SYSTEMS
Descriptors DEC
ACCELERATORS; CONTROL SYSTEMS; ELECTROSTATIC ACCELERATORS; ON-LINE CONTROL SYSTEMS; ON-LINE SYSTEMS

Optional Information

Notes
1 ref., 1 fig.