Published November 2019 | Version v1
Journal article

Investigation of radon concentrations of underground metro and Marmaray stations in Istanbul

  • 1. Ankara University, Ankara (Turkey). Institute of Accelerator Technologies
  • 2. Istanbul University, Istanbul (Turkey). Science Faculty

Description

In this study, radon (Rn) measurements were evaluated for the first time in the underground metro and Marmaray stations in Istanbul and the annual effective dose values were calculated to the employees and for passengers. Radon concentrations ranged from 39.47 to 382.02 Bq m-3 for the railway platforms. The average radon value for all station platforms found to be 114.60 Bq m-3. The annual effective dose values for the employees working at the platforms varied from 0.12 and 2.75 mSv y-1, while the data for the passengers were varied from 0.035 and 0.34 mSv y-1. (author)

Additional details

Publishing Information

Journal Title
Journal of Radioanalytical and Nuclear Chemistry
Journal Volume
322
Journal Issue
2
Journal Page Range
p. 291-304
ISSN
0236-5731
CODEN
JRNCDM

INIS

Country of Publication
Hungary
Country of Input or Organization
Hungary
INIS RN
50080856
Subject category
S54: ENVIRONMENTAL SCIENCES;
Descriptors DEI
ANNUAL VARIATIONS; EFFECTIVE RADIATION DOSES; ELECTRIC-POWERED VEHICLES; RADON; TURKEY; UNDERGROUND; URBAN AREAS
Descriptors DEC
ASIA; DEVELOPING COUNTRIES; DOSES; ELEMENTS; FLUIDS; GASES; LEVELS; MIDDLE EAST; NONMETALS; RADIATION DOSES; RARE GASES; VARIATIONS; VEHICLES

Optional Information

Notes
33 refs.