Published May 1977 | Version v1
Report Open

Energy calibration of the A.N.U. 14UD Pelletron accelerator

  • 1. Australian National Univ., Canberra. Dept. of Nuclear Physics
  • 2. Australian National Univ., Canberra. Dept. of Physics

Description

The energy calibration of the 14UD Pelletron accelerator at the Australian National University has been determined, with an accuracy better than 0.1%, up to 64 MeV equivalent proton energy using a simple alpha-particle back-scattering technique. From the observed width of the 14.2 MeV resonance in the 12C(p,αsub(o))9B reaction, the energy spread ΔE/E of the analysed beam was measured as (1.7 +- 0.3) x 10-4 at a terminal potential of 7.1 MV. (Author)

Availability note (English)

MF available from INIS under the Report Number.

Files

8347519.pdf

Files (381.3 kB)

Name Size Download all
md5:c0487354042cf2e827df031210bc8255
381.3 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
15 p.
Report number