Published October 1975 | Version v1
Report Open

Safety limits of half-mask cartridge respirators for organic solvent vapors

Creators

Description

Recent studies of the effective service life (safety limits) for typical half-mask cartridge respirators have shown these devices to be unsuitable for certain organic vapors, e.g., methanol, methylamine, vinyl chloride, and dichloromethane, because the effective service life is too short. For these vapors other forms of protection such as air-supplied respirators are recommended. The experimentally determined service life for many vapors is shorter--sometimes significantly shorter--than predicted by adsorption theory

Files

7237164.pdf

Files (866.4 kB)

Name Size Download all
md5:142ec97ddd095d4421d1840f571c08de
866.4 kB Preview Download

Additional details

Publishing Information

Imprint Title
Lawrence Livermore Laboratory energy and technology review
Imprint Pagination
p. 11-14.
Report number
UCRL--52000-75-10

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
7237164
Subject category
S61: RADIATION PROTECTION AND DOSIMETRY;
Descriptors DEI
ORGANIC SOLVENTS; PERFORMANCE TESTING; RESPIRATORS; VAPORS
Descriptors DEC
FLUIDS; GASES; NONAQUEOUS SOLVENTS; SOLVENTS; TESTING