Calculational justification of NPP component seismic stability

Description

Seismic stability calculation has been demonstrated by means of a linear-spectral analysis method taking as an example the crane, heat exchanger, superheater separator at the AST-500 unit. The calculation is performed according to a simplified scheme taking into account only one or two lowest natural frequencies of each equipment unit in the range up to 33 Hz

Additional details

Additional titles

Original title (Russian)
Сейсмостойкост' энергетического оборудования AEhS

Publishing Information

Journal Title
Ehnergomashinostroenie
Journal Issue
no.9
Series
Ehnergomashinostroenie.
ISSN
0131-1336
CODEN
EGMSA