Published March 12, 1984
| Version v1
Report
Restricted
Hands-on repair of component with a lowered pool water level
Description
The repair of a broken positioner mechanism on a TRIGA Reactor neutron collimator, with a lowered pool water level, presented a unique challenge. Radiation dose measurements were made which indicated the repair could be done safetly with only 3 feet of water providing shielding over the reactor core. The entire repair project went quite well, due in large part to extensive preplanning. Repair was done safely and radiation exposures were kept well below allowable levels. Savings were significant using this method of repair compared to the alternative of dismantling the facility
Availability note (English)
MF available from INIS under the Report Number; Available from NTIS, PC A02/MF A01 as DE84007172.
Files
Additional details
Publishing Information
- Imprint Pagination
- 12 p.
- Report number
- HEDL-SA--3078-FP
Conference
- Title
- 9. US TRIGA owner-user conference.
- Dates
- 12 Mar 1984.
- Place
- Anaheim, CA (USA).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 15053663
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- COLLIMATORS; NEUTRON RADIOGRAPHY; RADIATION DOSES; REPAIR; TRIGA TYPE REACTORS
- Descriptors DEC
- ENRICHED URANIUM REACTORS; HOMOGENEOUS REACTORS; HYDRIDE MODERATED REACTORS; REACTORS; RESEARCH AND TEST REACTORS; SOLID HOMOGENEOUS REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS
Optional Information
- Secondary number(s)
- CONF-840386--1.