Published November 1993 | Version v1
Journal article

The steam generator changeout at Beznau-1

Creators

Description

At the Beznau-1 nuclear power plant in Switzerland, the unit's two steam generators were replaced in the second quarter of 1993. The steam generator replacement portion of the outage - the period from when contractors were given access to the containment to when the steam generators were ready for hydrostatic pressure testing - was 44 days (April 12- May 26, 1993), shorter than the 46 days gained. Total length of the outage was 99 days (April 2 - July 9). Collective radiation dose received by project personnel was 110 person-rem, much less than the planned 250 person-rem. Project cost was about $50 million, including the new SGs and the replacement work, according to Nordostschweizerische Kraftwerke AG (NOK), plant owner and operator

Additional details

Publishing Information

Journal Title
Nuclear News (La Grange Park, Illinois)
Journal Volume
36
Journal Issue
14
Journal Page Range
p. 37-40.
ISSN
0029-5574
CODEN
NUNWA8