Published July 2009 | Version v1
Journal article

Monte Carlo Simulation of the Field Gamma Spectrometer Calibration

  • 1. School of Physics and Engineering, Sun Yat-sen University, Guangzhou (China)
  • 2. Electron Engineering Department, Dongguan University of Technology, Dongguan (China)

Description

Monte Carlo method is used to simulate the spectrum measured by NaI (Tl) gamma spectrometer for the field spectrometer calibration, and the response coefficients of the NaI (Tl) gamma spectrometer is calculated. By comparing the calculation results with the experimental results, the possibility of using Monte Carlo method for field NaI (Tl) gamma spectrometer calibration is studied. The result shows that the difference of response coefficients between simulation results and experimental results is less than 12% when the energy resolution of spectrometer for Cs-137 is varied within 8-14%. (authors)

Additional details

Publishing Information

Journal Title
Nuclear Electronics and Detection Technology
Journal Volume
29
Journal Issue
4
Journal Page Range
p. 832-835
ISSN
0258-0934

Optional Information

Notes
6 figs., 2 tabs., 9 refs.