Low-energy x-ray instrumentation for SHIVA. Final report
Description
This document reports the results of a study by Lockheed Palo Alto Research Laboratory on the optimization of low-energy x-ray diagnostic instrument for the SHIVA laser facility at the Lawrence Livermore Laboratory. Preliminary outlines for the basic system and several components are presented, experimental considerations and techniques are recommended, and further studies are suggested
Availability note (English)
MF available from INIS under the Report Number; Available from NTIS., PC A02/MF A01.Files
10434659.pdf
Files
(366.9 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:e4dcf11c899b152aeaef25be86392894
|
366.9 kB | Preview Download |
Additional details
Publishing Information
- Imprint Pagination
- 18 p.
- Report number
- UCRL--13876
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 10434659
- Subject category
- S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
- Descriptors DEI
- ALIGNMENT; CALIBRATION; ELECTRONIC EQUIPMENT; MEASURING METHODS; MIRRORS; OPTIMIZATION; PLASMA DIAGNOSTICS; REFLECTION; SHIVA FACILITY; X RADIATION; X-RAY SPECTRA
- Descriptors DEC
- ELECTROMAGNETIC RADIATION; IONIZING RADIATIONS; RADIATIONS; SPECTRA
Optional Information
- Secondary number(s)
- LMSC/D--628276.