Published November 2009 | Version v1
Journal article

Sigmoid dose using 3D imaging in cervical-cancer brachytherapy

  • 1. Department of Radiation Oncology, Brigham and Women's Hospital/Dana-Farber Cancer Institute, MA (United States)

Description

Background and Purpose: To evaluate the proximity, variance, predictors of dose, and complications to the sigmoid in cervical-cancer brachytherapy using 3D planning. Materials and methods: Over 36 months, 50 patients were treated for cervical cancer with either low-dose-rate (LDR) or high-dose-rate (HDR) brachytherapy. The distance from the central tandem to the sigmoid, the D0.1cc and the D2cc to the sigmoid, rectum and bladder doses, and toxicity were analyzed. Results: The median sigmoid EQD2 D0.1cc and D2cc were 84 Gy and 68.3 Gy for HDR versus 71.1 Gy and 65.9 Gy for LDR (p = 0.02 and 0.98, respectively). Twenty percent of the HDR fractions required manipulation of the superior dwell positions to decrease the sigmoid dose. The median distance from the sigmoid to the tandem was 1.7 cm (range [rg], 0.1-6.16 cm) for HDR and 2.7 cm (rg, 1.17-4.52 cm) for LDR; from the sigmoid to the 100% isodose region the median distances were -0.1 cm (rg, -1.4 to 2.5 cm) and 0.44 cm (rg. -0.73-5.2 cm), respectively. The proximity of the sigmoid to the tandem is significantly related to sigmoid dose (p < 0.0001). Within-patient (among-fraction) variation in sigmoid-to-tandem distance during HDR was substantial (coefficient of variation =40%). No grade 3-4 sigmoid toxicity was seen after a median 31-month follow-up period. Conclusions: 3D imaging in cervical-cancer brachytherapy shows the sigmoid in close proximity to the tandem. The sigmoid-to-tandem distance varies substantially between fractions, indicating the importance of sigmoid dose-volume evaluation with each fraction.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.radonc.2009.06.032

Additional details

Identifiers

DOI
10.1016/j.radonc.2009.06.032;
PII
S0167-8140(09)00362-4;

Publishing Information

Journal Title
Radiotherapy and Oncology
Journal Volume
93
Journal Issue
2
Journal Page Range
p. 307-310
ISSN
0167-8140
CODEN
RAONDT

INIS

Country of Publication
Ireland
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
41074306
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
BLADDER; BRACHYTHERAPY; DOSE RATES; NEOPLASMS; PATIENTS; RADIATION DOSES; RECTUM; TOXICITY
Descriptors DEC
BODY; DIGESTIVE SYSTEM; DISEASES; DOSES; GASTROINTESTINAL TRACT; INTESTINES; LARGE INTESTINE; MEDICINE; NUCLEAR MEDICINE; ORGANS; RADIOLOGY; RADIOTHERAPY; THERAPY; URINARY TRACT

Optional Information

Copyright
Copyright (c) 2009 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.