Estimate of the dose received in crystalline lens by pediatric interventional cardiologists
Creators
- 1. Hospital Universitario La Paz, Servicio de Radiofisica y Radioproteccion, Paseo de la Castellana 261, 28046 Madrid (Spain)
Description
The objective of this work is to estimate the maximum dose accumulated during one year in the crystalline lens of the pediatric interventional cardiologists that work in the Hospital Universitario La Paz. Optically Stimulated Luminescence Dosimeters (OSLDs) were used for to carry out this estimation, placed in the eyes of an anthropomorphic mannequin whose position in the room simulates the more habitual conditions of the clinical practice. Previously to the simulation, different tests to validate the used dosimetric system were realized, including those related with the stability, reproducibility and lector linearity, as well as the angular and energy dependence of the OSLDs. During the simulation the mannequin eyes were irradiated and were measured with OSLDs the rate of superficial equivalent dose in crystalline lens for the different qualities of beam habitually used, as much in fluoroscopy as in acquisition. With the obtained data during three years, corresponding to the fluoroscopy times and the acquisitions number of the interventional procedures carried out; as much therapeutic as diagnostic, and rate by measuring of obtained dose, has been considered the superficial equivalent dose and the equivalent dose at 3 mm deep accumulated in the crystalline lens of the pediatric interventional cardiologist with more work load of the Hospital, during the years 2011 and 2012. None of the obtained maximum values exceed the new dose annual limit in crystalline lens of 20 mSv, recommended by ICRP in April of 2011. (author)
Files
45110577.pdf
Files
(390.9 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:ca20616e3201233ae0c2cd62a9cc6c9c
|
390.9 kB | Preview Download |
Additional details
Additional titles
- Original title (Spanish)
- Estimacion de la dosis recibida en cristalino por cardiologos intervencionistas pediatricos
Publishing Information
- Publisher
- Sociedad Mexicana de Irradiacion y Dosimetria
- Imprint Place
- Mexico, D. F. (Mexico)
- Imprint Pagination
- 17 p.
- Report number
- INIS-MX--2787
Conference
- Title
- 14. International Symposium on Solid State Dosimetry
- Original Conference Title
- 14. Conferencia Internacional sobre Dosimetria de Estado Solido
- Dates
- 13-16 Apr 2014
- Place
- Cusco (Peru)
INIS
- Country of Publication
- Mexico
- Country of Input or Organization
- Mexico
- INIS RN
- 45110577
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- BEAMS; CRYSTALLINE LENS; DATA; DOSE EQUIVALENTS; DOSEMETERS; DOSES; ENERGY DEPENDENCE; FLUOROSCOPY; HOSPITALS; ICRP; IRRADIATION; LUMINESCENCE; MEDICAL PERSONNEL; PEDIATRICS; SIMULATION; STABILITY
- Descriptors DEC
- BIOMEDICAL RADIOGRAPHY; BODY; BUILDINGS; DIAGNOSTIC TECHNIQUES; EMISSION; EYES; FACE; HEAD; INFORMATION; INTERNATIONAL ORGANIZATIONS; MEASURING INSTRUMENTS; MEDICAL ESTABLISHMENTS; MEDICINE; NUCLEAR MEDICINE; ORGANS; PERSONNEL; PHOTON EMISSION; RADIOLOGY; SENSE ORGANS
Optional Information
- Funding organization
- Organizacion Panamericana de la Salud, Washington D. C. (United States); Universidad Nacional de San Antonio de Abad del Cusco, Cusco (Peru); Instituto Peruano de Energia Nuclear, Lima (Peru); Elekta AB (Sweden); RadPro International GmbH (Germany); ThermoFisher Scientific, Inc. (United States); Varian Medical Systems (United States)