Published July 1, 2019 | Version v1
Journal article

Conversion of computational human phantoms into DICOM-RT for normal tissue dose assessment in radiotherapy patients

  • 1. Division of Cancer Epidemiology and Genetics, National Cancer Institute, National Institutes of Health, Rockville, MD 20850 (United States)
  • 2. Department of Physics, East Carolina University, Greenville, NC 27858 (United States)
  • 3. Department of Radiation Oncology, Northwestern Memorial Hospital, Chicago, IL 60611 (United States)
  • 4. Department of Radiation Oncology, University of Michigan, Ann Arbor, MI 48109 (United States)
  • 5. Division of Science and Mathematics, University of District of Columbia, Washington, DC 20008 (United States)

Description

Radiotherapy (RT) treatment planning systems (TPS) are designed for the fast calculation of dose to the tumor bed and nearby organs at risk using x-ray computed tomography (CT) images. However, CT images for a patient are typically available for only a small portion of the body, and in some cases, such as for retrospective epidemiological studies, no images may be available at all. When dose to organs that lie out-of-scan must be estimated, a convenient alternative for the unknown patient anatomy is to use a matching whole-body computational phantom as a surrogate. The purpose of the current work is to connect such computational phantoms to commercial RT TPS for retrospective organ dose estimation. A custom software with graphical user interface (GUI), called the DICOM-RT Generator, was developed in MATLAB to convert voxel computational phantoms into the digital imaging and communications in medicine radiotherapy (DICOM-RT) format, compatible with commercial TPS. DICOM CT image sets for the phantoms are created via a density-to-Hounsfield unit (HU) conversion curve. Accompanying structure sets containing the organ contours are automatically generated by tracing binary masks of user-specified organs on each phantom CT slice. The software was tested on a library of body size-dependent phantoms, the International Commission on Radiological Protection reference phantoms, and a canine voxel phantom, taking only a few minutes per conversion. The resulting DICOM-RT files were tested on several commercial TPS. As an example application, a library of converted phantoms was used to estimate organ doses for members of the National Wilms Tumor Study (NWTS) cohort. The converted phantom library, in DICOM format, and a standalone MATLAB-compiled executable of the DICOM-RT Generator are available for others to use for research purposes (http://ncidose.cancer.gov). (note)

Availability note (English)

Available from http://dx.doi.org/10.1088/1361-6560/ab2670

Additional details

Identifiers

Publishing Information

Journal Title
Physics in Medicine and Biology
Journal Volume
64
Journal Issue
13
Journal Page Range
[9 p.]
ISSN
0031-9155
CODEN
PHMBA7