Uterine Artery Embolization for Leiomyomata: Optimization of the Radiation Dose to the Patient Using a Flat-Panel Detector Angiographic Suite
Creators
- 1. Georges Pompidou European Hospital, Department of Cardio Vascular Radiology (France)
- 2. Institute for Radiological Protection and Nuclear Safety (IRSN) (France)
Description
The purpose of this study was to assess the ability of low-dose/low-frame fluoroscopy/angiography with a flat-panel detector angiographic suite to reduce the dose delivered to patients during uterine fibroid embolization (UFE). A two-step prospective dosimetric study was conducted, with a flat-panel detector angiography suite (Siemens Axiom Artis) integrating automatic exposure control (AEC), during 20 consecutive UFEs. Patient dosimetry was performed using calibrated thermoluminescent dosimeters placed on the lower posterior pelvis skin. The first step (10 patients; group A) consisted in UFE (bilateral embolization, calibrated microspheres) performed using the following parameters: standard fluoroscopy (15 pulses/s) and angiography (3 frames/s). The second step (next consecutive 10 patients; group B) used low-dose/low-frame fluoroscopy (7.5 pulses/s for catheterization and 3 pulses/s for embolization) and angiography (1 frame/s). We also recorded the total dose-area product (DAP) delivered to the patient and the fluoroscopy time as reported by the manufacturer's dosimetry report. The mean peak skin dose decreased from 2.4 ± 1.3 to 0.4 ± 0.3 Gy (P = 0.001) for groups A and B, respectively. The DAP values decreased from 43,113 ± 27,207 μGy m2 for group A to 9,515 ± 4,520 μGy m2 for group B (P = 0.003). The dose to ovaries and uterus decreased from 378 ± 238 mGy (group A) to 83 ± 41 mGy (group B) and from 388 ± 246 mGy (group A) to 85 ± 39 mGy (group B), respectively. Effective doses decreased from 112 ± 71 mSv (group A) to 24 ± 12 mSv (group B) (P = 0.003). In conclusion, the use of low-dose/low-frame fluoroscopy/angiography, based on a good understanding of the AEC system and also on the technique during uterine fibroid embolization, allows a significant decrease in the dose exposure to the patient.
Additional details
Identifiers
Publishing Information
- Journal Title
- Cardiovascular and Interventional Radiology
- Journal Volume
- 33
- Journal Issue
- 5
- Journal Page Range
- p. 949-954
- ISSN
- 0174-1551
- CODEN
- CAIRDG
INIS
- Country of Publication
- United States
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 42028981
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ARTERIES; DOSIMETRY; EMBOLI; FLUOROSCOPY; OPTIMIZATION; OVARIES; PATIENTS; PELVIS; RADIATION DOSES; SKIN; THERMOLUMINESCENT DOSEMETERS; UTERUS
- Descriptors DEC
- BIOMEDICAL RADIOGRAPHY; BLOOD VESSELS; BODY; CARDIOVASCULAR SYSTEM; DIAGNOSTIC TECHNIQUES; DOSEMETERS; DOSES; FEMALE GENITALS; GONADS; LUMINESCENT DOSEMETERS; MEASURING INSTRUMENTS; MEDICINE; NUCLEAR MEDICINE; ORGANS; RADIOLOGY
Optional Information
- Copyright
- Copyright (c) 2010 Springer Science+Business Media, LLC and the Cardiovascular and Interventional Radiological Society of Europe (CIRSE)