Neutron sensitivity of 6Li-based suspended foil microstrip neutron detectors using Schott Borofloat® 33 microstrip electrodes
Creators
- 1. S.M.A.R.T. Laboratory, Department of Mechanical and Nuclear Engineering, Kansas State University, Manhattan, KS 66506 (United States)
- 2. Radiation Detection Technologies, Inc., Manhattan, KS 66502 (United States)
Description
Highlights: • 6Li-based suspended foil microstrip neutron detectors simulated using MCNP6. • 6Li-based suspended foil microstrip neutron detectors fabricated and tested. • Intrinsic thermal-neutron detection efficiency vertical profiles measured. - Abstract: 6Li foils, each 75-µm thick, were positioned between a Schott Borofloat® 33 microstrip electrode and a planar drift electrode to construct suspended foil microstrip neutron detectors. MCNP6 simulations of two detector configurations, one containing a single 6Li foil and the other containing five 6Li foils, indicated expected maximum intrinsic thermal-neutron detection efficiencies of 18.36% and 54.08%, respectively. For comparison, the intrinsic thermal-neutron detection efficiency as a function of thermal-neutron beam position along the foil span was experimentally measured for both detector configurations. A non-uniform intrinsic thermal-neutron detection efficiency distribution was observed along the span of the 6Li foil(s) between the microstrip and drift electrodes. Maximum intrinsic thermal-neutron detection efficiencies of 12.58 ± 0.15% and 29.75 ± 0.26% for the single and five 6Li foils were measured, respectively. Gamma-ray rejection ratios of 6.46 × 10−5 ± 4.32 × 10−7 and 7.96 × 10−5 ± 4.65 × 10−7 were also measured, respectively, for a 137Cs exposure rate of 50 mR h−1. All measurements were conducted with the 6Li foil(s) contained within a sealed aluminum enclosure pressurized with 10 psig of P-10 gas.
Availability note (English)
Available from http://dx.doi.org/10.1016/j.radphyschem.2018.02.013Additional details
Identifiers
- DOI
- 10.1016/j.radphyschem.2018.02.013;
- PII
- S0969806X1731174X;
Publishing Information
- Journal Title
- Radiation Physics and Chemistry (1993)
- Journal Volume
- 147
- Journal Page Range
- p. 70-76
- ISSN
- 0969-806X
- CODEN
- RPCHDM
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 50080237
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Descriptors DEI
- BEAM POSITION; CESIUM 137; EFFICIENCY; ELECTRODES; FOILS; GAMMA RADIATION; LITHIUM 6; NEUTRON BEAMS; NEUTRON DETECTION; NEUTRON DETECTORS; SIGNALS; THERMAL NEUTRONS
- Descriptors DEC
- BARYONS; BEAMS; BETA DECAY RADIOISOTOPES; BETA-MINUS DECAY RADIOISOTOPES; CESIUM ISOTOPES; DETECTION; ELECTROMAGNETIC RADIATION; ELEMENTARY PARTICLES; FERMIONS; HADRONS; INTERMEDIATE MASS NUCLEI; IONIZING RADIATIONS; ISOTOPES; LIGHT NUCLEI; LITHIUM ISOTOPES; MEASURING INSTRUMENTS; NEUTRONS; NUCLEI; NUCLEON BEAMS; NUCLEONS; ODD-EVEN NUCLEI; ODD-ODD NUCLEI; PARTICLE BEAMS; RADIATION DETECTION; RADIATION DETECTORS; RADIATIONS; RADIOISOTOPES; STABLE ISOTOPES; YEARS LIVING RADIOISOTOPES
Optional Information
- Notes
- © 2018 Elsevier Ltd. All rights reserved.