Published December 1, 2015 | Version v1
Journal article

Prospective, Multicenter Validation Study of Magnetic Resonance Volumetry for Response Assessment After Preoperative Chemoradiation in Rectal Cancer: Can the Results in the Literature be Reproduced?

  • 1. GROW School for Oncology and Developmental Biology, Maastricht University Medical Center, Maastricht (Netherlands)
  • 2. Department of Surgery, Maastricht University Medical Center, Maastricht (Netherlands)
  • 3. Department of Radiology, Maastricht University Medical Center, Maastricht (Netherlands)
  • 4. Department of Surgery, Medical Center Alkmaar, Alkmaar (Netherlands)
  • 5. Department of Radiology, Fudan University, Shanghai (China)
  • 6. Department of Radiology, University Hospital Leuven, Leuven (Belgium)
  • 7. Department of Radiology, Atrium Medical Center, Heerlen (Netherlands)

Description

Purpose: To review the available literature on tumor size/volume measurements on magnetic resonance imaging for response assessment after chemoradiotherapy, and validate these cut-offs in an independent multicenter patient cohort. Methods and Materials: The study included 2 parts. (1) Review of the literature: articles were included that assessed the accuracy of tumor size/volume measurements on magnetic resonance imaging for tumor response assessment. Size/volume cut-offs were extracted; (2) Multicenter validation: extracted cut-offs from the literature were tested in a multicenter cohort (n=146). Accuracies were calculated and compared with reported results from the literature. Results: The review included 14 articles, in which 3 different measurement methods were assessed: (1) tumor length; (2) 3-dimensonial tumor size; and (3) whole volume. Study outcomes consisted of (1) complete response (ypT0) versus residual tumor; (2) tumor regression grade 1 to 2 versus 3 to 5; and (3) T-downstaging (ypT3 (after chemoradiation therapy) and a volume reduction of Δ80% to 86.6%. Accuracies for whole-volume measurements to assess tumor regression grade 1 to 2 were 52% to 61%, and for T-downstaging 51% to 57%. Overall accuracies for tumor length ranged between 48% and 53% and for 3D size measurement between 52% and 56%. Conclusions: Magnetic resonance volumetry using whole-tumor volume measurements can be helpful in rectal cancer response assessment with selected cut-off values. Measurements of tumor length or 3-dimensional tumor size are not helpful. Magnetic resonance volumetry is mainly accurate to assess a complete tumor response (ypT0) after chemoradiation therapy (accuracies up to 80%).

Availability note (English)

Available from http://dx.doi.org/10.1016/j.ijrobp.2015.09.008

Additional details

Identifiers

DOI
10.1016/j.ijrobp.2015.09.008;
PII
S0360-3016(15)03318-0;

Publishing Information

Journal Title
International Journal of Radiation Oncology, Biology and Physics
Journal Volume
93
Journal Issue
5
Journal Page Range
p. 1005-1014
ISSN
0360-3016
CODEN
IOBPD3

INIS

Country of Publication
United States
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
48093624
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
CHEMOTHERAPY; COMBINED THERAPY; NEOPLASMS; NMR IMAGING; RADIOTHERAPY; RECTUM; REVIEWS; VALIDATION
Descriptors DEC
BODY; DIAGNOSTIC TECHNIQUES; DIGESTIVE SYSTEM; DISEASES; DOCUMENT TYPES; GASTROINTESTINAL TRACT; INTESTINES; LARGE INTESTINE; MEDICINE; NUCLEAR MEDICINE; ORGANS; RADIOLOGY; TESTING; THERAPY

Optional Information

Copyright
Copyright (c) 2015 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.